  • Page 1 USER MANUAL User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022...
  • Page 2 Copyright © 2022 Simpro Handling Equipment Ltd. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the written permission of Simpro Handling Equipment Ltd. For the purposes of standards compliance and international conformity, this document uses Système International (SI) units.
  • Page 3 1030 1045 EO2200 Standard Layout User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 4: Table Of Contents

    C ont ent s Product Overview ......................5 Key Features .......................... 5 Construction .......................... 5 Mechanism ..........................6 Safe Lifting Capacity ......................6 Duty cycle ..........................6 Service life ..........................6 Noise emissions ........................6 Environmental restrictions ....................7 Ingress protection ......................... 7 1.10 Notes ............................
  • Page 5 Definitions ..........................31 Coverage ..........................31 Exclusions ..........................31 End User claim procedure ....................32 Agent claim handling procedure ..................32 10. Notes ........................... 33 User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 6: Product Overview

    1.2m up to 2.5m. The Eurover quick-hitch retaining system allows bins to be secured simply by rolling them into place, with no clamping required. At the end of the tipping cycle, pressing down on a foot catch allows the bins to be instantly released.
  • Page 7: Mechanism

    300kg – 350kg 50,000 cycles 1.7 Noise emissions The noise emissions of the Eurover do not usually exceed ~60 dB(A) at the operator’s ear. Hearing protection is recommended if operating the machine for extended periods. User Manual // Simpro Eurover...
  • Page 8: Environmental Restrictions

    4. If the machine is to be leased, sold, or otherwise transferred, then this manual shall accompany the machine. 5. This is a generic manual. Simpro reserves the right to change the design of our products at any time. In cases where a discrepancy exists between the manual and the actual product, the manual is to be used as a reference only.
  • Page 9: Operating Instructions

    2 . O p e rat in g Instru ct io n s 2.1 Before use Before operating a Eurover, the following points should be checked to ensure the machine is stable and safe to use: 1. If being used with a mobile base unit, check that: a.
  • Page 10: Operating Norms

    2.3 Operating norms The following operating norms must be observed for the safe use of the Eurover. Only trained personnel should be authorised to operate the machine. Operators must read and comply with all instructions and warning labels. The machine must only be operated on hard, level concrete or steel surfaces.
  • Page 11 10 metres. Ensure there is complete continuity between the machine and an effective earthing system which complies with local and national regulations. User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 12: Care And Maintenance

    ‘tipping bracket’. This bracket can be moved up or down to quickly adjust the Eurover tipping height, as set out below. 1. Lower the cradle to the ground and, if necessary, remove the Eurobin.
  • Page 13: Cleaning

    3.3 Cleaning The Eurover should be cleaned with a water jet, a microfiber cloth, and a suitable food- grade cleaning agent. Cleaning should be carried out with the cradle lowered. Do not direct high-pressure water jets at the powerpack enclosure or controls.
  • Page 14: Cradle Jams While Lowering

    a. The mast being bent or damaged, jamming one of the mast rollers. b. Part of the tipping track being bent or misaligned, interfering with the correct movement of the tipping roller. c. A worn or misaligned tipping roller. d. Lack of lubrication of the rollers or mast sliding block. e.
  • Page 15: Electrical System

    3-phase extension lead. The Eurover is fitted with a phase-rotation relay, so it will not operate if the AC phase polarity of the input power is inverted. This can be corrected by switching two of the phase wires in the power plug as set out in §4.1.3.
  • Page 16: Preventative Maintenance Inspections

    This helps ensure operator safety and extend the service life of the machine. The inspection procedures and log sheets are provided in the following section. Operators should immediately stop using the Eurover and request an inspection if any abnormal operation or fault is observed.
  • Page 17 Service Checks Notes on repairs or Parts and Date Location Person complete maintenance required materials used User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 18: Installation, Handling & Storage

    Eurover until the mast is upright, with the base a short distance off the ground. 3. Transport the Eurover to the install location, taking care not to strike any obstacles. Never stand or reach underneath the machine while it is lifted.
  • Page 19: Connecting The Power

    7. Fix the Eurover into position with six M16 x 100-150mm sleeve anchors, in accordance with the fixing manufacturer’s instructions. Dynabolts should be fixed in accordance with the instructions below: ™ 8. The Eurover is now installed, and can be detached from the lifting equipment.
  • Page 20: Moving

    The Eurover with mobile base unit can be easily moved using the grab-handles provided. To ensure stability the cradle should be positioned 100mm off the ground when moving. On a hard, flat surface, the mobile Eurover can be moved by a force of approximately 100 Newtons at a height of 1.6 metres.
  • Page 21: Transporting

    Never lie the Eurover onto its front or back as this may damage the cradle and guarding. 4.5 Storing If the Eurover is not to be used for a period of six months or more, it should be stored in a clean, dry place with good ventilation, at temperatures not below 0℃. Carry out the following procedures when placing the Eurover into storage: 1.
  • Page 22: Safety Assessment

    5. S af ety A s se ss me nt The Eurover has been designed to be as safe as possible without restricting the ease-of-use and versatility of the machine. An application-specific Hazard and Risk Assessment should be completed before the Eurover is used for the first time, as set out in §5.3.
  • Page 23: The Iso12100 Risk Assessment Model

    Risks evaluated as Very High, Extreme or Unacceptable are likely to require additional or uprated safety functions as set out in §5.4. These must be specified at the time of order. User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 24: Identified Hazards

    5.3.2 Identified Hazards The following hazards have been identified that are intrinsic to the Eurover design. For each hazard a full Risk Evaluation has been completed and control measures described. Blank template spaces are also provided to identify, assess, and describe control measures for application-specific hazards.
  • Page 25 Crushing if the machine falls over Risk DPH: Factor: Operator Minimal risk when the Eurover has been properly installed, as the machine is either bolted down or affixed to a large, stable mobile base unit. Risk DPH: Other Factor: persons As above.
  • Page 26: Residual Hazards

    Application-specific hazard: Risk DPH: Factor: Operator Risk DPH: Other Factor: persons Control measures Comments Application-specific hazard: Risk DPH: Factor: Operator Risk DPH: Other Factor: persons Control measures Comments Application-specific hazard: Risk DPH: Factor: Operator Risk DPH: Other Factor: persons Control measures Comments 5.3.3 Residual Hazards...
  • Page 27: Iso13849 (As/Nzs4024) Conformance Guide

    The following section is intended to assist prospective Eurover operators in carrying out this process. ISO13849-1:2015 ‘Safety of machinery’ is a standard issued by the International Standards Organisation.
  • Page 28: Achieving The Required Performance Level

    Scarcely possible 5.4.4 Achieving the required Performance Level Because all hazards intrinsic to the Eurover design are addressed by safety functions with PLc performance, alternative or uprated safety functions are only required if an application- specific risk assessment identifies any of the following: Hazards requiring safety functions not provided for in the standard Eurover design.
  • Page 29: Spare Parts

    6. S p are Parts The following table includes the most common Eurover spare parts as at the time of publication. Additional parts may be added at a later date. Where a part has been introduced or discontinued, the Date Of Manufacture (DOM) period is noted in brackets.
  • Page 30: Accessories

    7 . A cc e ss o r ie s A range of accessories and complementary products are available for the Eurover, a selection of which are listed below. Model Code Part Code Description EO-BASE 0250190530 Eurover Mobile Base Unit, left-handed, with castor wheels and guard rails...
  • Page 31: Technical Data

    8 . Te c hn ical Dat a The Eurover is available in four primary models, with maximum tipping heights of 2200mm or 2500mm and left- or right-handed orientation. Mobile base units are available for all models. Parameter EO2200 EO2200R...
  • Page 32: Warranty

    “Agent” means a person or company authorized by Simpro to sell a Product. “Service Agent” means a person or company authorized by Simpro to repair a Product. “End User” means the first purchaser of a Product from a Sales Agent authorised by Simpro to sell the Product.
  • Page 33: End User Claim Procedure

    Parts requiring replacement will be supplied by Simpro free of charge; in some cases, it may be necessary to source Parts locally if needed urgently, but Simpro must authorize this if the cost of the item exceeds $50.00 and is to be charged to Simpro.
  • Page 34: Notes

    1 0 . N ote s...
  • Page 35 User Manual // Simpro Eurover Original Instructions // English // v34.0 // April 2022 // Page...
  • Page 36 +64 9 634 7445 Takanini 2105 sales@simpro.world Auckland, New Zealand shop.simpro.world PO Box 74 @simpro.world Takanini 2245 Auckland, New Zealand @SimproWorld_Lifters User Manual // Simpro Eurover Original Version // English // v34.0 // April 2022 // ©2022 Simpro Handling Equipment Ltd...