Angled Plume Management Kit Example; Plume Management Kit Under A Balcony-Overhang; Extended Plume Management Kit Under A Balcony - Worcester Greenstar Condensfit II Installation Instructions Manual

Wall mounted gas condensing appliance flue
Hide thumbs Also See for Greenstar Condensfit II:
Table of Contents

Advertisement

5.2.6

Angled plume management kit example

1
3
4
2
6
173mm
10°
1,000mm
Fig. 31 Angled option
5.2.7

Plume management kit under a balcony-overhang

The extension pipe [2] must be supported as close to the 90° elbow [3]
and before the end of the balcony/overhang to provide adequate
support.
▶ If the supplied brackets are not long enough then third party 60mm
pipe brackets [7] can be used.
The shaded area is the exclusion zone for plume discharge. The
discharge must be outside this zone.
Greenstar Condensfit II – 6 721 819 755 (2019/12)
5
5
346mm
2,000mm
2,000mm
1,000mm
52mm
104mm
100mm
m m
≥ 5 0 0
Fig. 32 Under a balcony/overhang option
5.2.8

Extended plume management kit under a balcony

The shaded area is the exclusion zone for plume discharge. The
discharge must be outside this zone.
Because of the extended flue terminal, two 45° elbows [6] are required
in the extension to bring the plume management close enough to the wall
so that the support bracket can be used.
1
3
4
2
2,000mm
1,000mm
52mm
104mm
100mm
≥140mm
Fig. 33
Plume management system
1
3
2
4
7
0010032450-001
5
6
13