Connecting the heat pump to the heating system
Connecting the heat pump to the heating system
It is important that all previously mentioned preparations have been
carried out before the heat pump is connected to the heating system. Also
ensure the system has been power fl ushed before it is connected to the
heat pump. Flushing protects the heat pump from contamination.
Oxygen must not enter the system. The heat pump is only intended
to work in oxygen free systems. If oxygen enters the system it causes
corrosion in the heat pump which could block the fi lter on the heating
system side.
Fitting the unvented kit
Parts to assemble:
Expansion vessel
Expansion vessel hose
Wall mounting kit for expansion vessel
Connection:
Mount the expansion vessel with the wall mounting kit. Connect the
expansion vessel hose to the expansion vessel.
Connect the expansion vessel, inlet control set and tundish as shown in the
schematics on page 16-17.
Only qualifi ed installers may carry out
the installation. The installer should
observe applicable regulations.
High fl ow rate inlet control set
Tundish
The relief valve connections should
not be used for other purpose.
14
Note
Note