Terminal elbow fitting
Terminal elbow ( figure 43
▶ Remove and retain the retaining screws [2] and discard the terminal
end [3].
▶ Fit the terminal elbow [1] to the terminal outlet and set the rotation of
the terminal elbow depending on the plume installation option
required.
▶ Secure the terminal end [1] with the screws [2] removed previously.
1
3
Fig. 43 Plume manangement terminal elbow
Extension fitting
Extension tube - Vertical( figure 44)
▶ Push the 45° elbow [4] fully into the terminal elbow [3], the stop tabs
set the depth and allow for expansion.
▶ Push the second 45° elbow fully into the first, the stop tabs set the
depth and allow for expansion.
▶ Orient the 45° elbows to bring the extension close to the wall to allow
a support clamp to be fitted.
▶ Secure the extension [2] to the wall with the support clamp and
screws provided [1].
Extension tube - at 45° with additional elbow (45° elbow example 
figure 44)
▶ Push the 45° elbow [4] fully into the terminal elbow [3], the stop tabs
set the depth and allow for expansion.
▶ Push the second 45° elbow fully into the first, the stop tabs set the
depth and allow for expansion.
▶ Orient the 45° elbows to bring the extension close to the wall to allow
a support clamp to be fitted.
▶ Push the extension tube [2] fully into the 45° elbow [3], then
withdraw the tube approximately 10mm to allow for expansion.
▶ Secure the extension [2] to the wall with the support clamp and
screws provided [1].
▶ Push the 45° terminal elbow [4] fully into the extension tube [2], the
stop tabs set the depth and allow for expansion.
▶ Further extensions are fitted in the same way as previously
described.
Greenstar Condensfit II – 6 721 819 755 (2019/12)
2
±80°
2
Fig. 44 Plume extension fitting
Discharge elbow fitting
Outlet assembly (vertical orientation figure 45)
▶ Secure the extension [4] to the wall with the support clamp and
▶ Push the outlet assembly elbow [1] fully into the extension tube [4],
▶ Rotate the outlet assembly [1] to the required direction permitted.
▶ Secure the outlet assembly elbow [1]to the extension [4] with the
Outlet assembly (angled orientation figure 45)
▶ Secure the extension [4] to the wall with the support clamp and
▶ Push the outlet assembly elbow [1] fully into the extension tube [4],
▶ Rotate the outlet assembly elbow [1] to the required direction
1
2
3
screws provided [3].
the stop tabs set the depth and allow for expansion.
self-tapping screw [2] provided.
screws provided [3].
the stop tabs set the depth and allow for expansion.
permitted.
Plume management system
4
2
1
±80°
17