4. Snap Motor Circuit (Horizontal Air Deflector, Ventilation Damper)
R 7 3 5
2 2
φ 4
M i c r o c o m p u t e r
2 1
φ 3
2 0
φ 2
1 9
φ 1
1 8
φ 4
1 7
φ 3
1 6
φ 2
1 5
φ 1
Fig. 4-1 shows the Auto sweep motor drive circuit; the signals shown in Fig.4-2 are output from pin 15 - 22 of
microcomputer.
Micro computer pins
Horizontal air deflectors
15
19
16
20
17
21
18
22
As the microcomputer's outputs change as shown in Fig.4-2, the coils of the auto sweep motor is excite to turn the
rotor. Table 4-1 shows the rotation angle of Horizontal Air Deflector, Ventilation Damper.
Table 4-1 Auto sweep Motor Rotation
Horizontal air deflectors
Ventilation Damper
D 7 3 3
Q 7 3 3
I C 7 1 1
0 V
7
1 0
6
1 1
5
1 2
4
1 3
3
1 4
2
1 5
1
1 6
1
2
φ
( 1)
φ
( 2)
φ
( 3)
φ
( 4)
Fig.4-2 Microcomputer Output Signals
Rotation angle per step ( ˚ )
1 2 V
Fig.4-1
Step width : 10ms
3
4
5
0.0882
- 40 -
C N 5
1
2
M
3
4
5
V e n t i l a t i o n d a m p e r m o t o r
C N 4
1
2
M
3
4
5
S t e p p i n g m o t o r f o r a u t o s w e e p
6
7
8
Time per step (ms.)
10