MAIN PARTS COMPONENT
THERMOSTAT
Thermostat Specifications
MODEL
THERMOSTAT MODEL
OPERATION MODE
TEMPERATURE
℃  ( ° F)
FAN MOTOR
Fan Motor Specifications
MODEL
POWER SOURCE
OUTPUT
CONNECTION
BLU : BLUE
GRAY
GRY :
BLK : BLACK
MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT
NAME
REVERSING VALVE COIL
REACTOR L1
REACTOR L2
FILM CAPACITOR
INDICATION
16
INDICATION
24
INDICATION
32
RAS-10JH1, RAS-14JH1
DC 5V, 35V
25W
RED
35V
BLK
0V
WHT
5V
YEL
0-5V
BLU
FG
(Control circuit built in )
YEL : YELLOW
ORN :
ORANGE
PNK
:
PINK
RATING
135
(20 ℃)
13 (mH), 0.224Ω
25.5 (mH), 0.37Ω 
45 ( μF)
- 24 -
RAS-10JH1, RAS-14JH1
COOL
ON
16.7 (62.1)
OFF
16.0 (60.8)
ON
24.7 (76.5)
OFF
24.0 (75.2)
ON
32.7 (90.9)
OFF
32.0 (89.6)
140-
350V
M
0-6V
0-15V
BRN : BROWN
GRN : GREEN
VIO
: VIOLET
IC
HEAT
18.7 (65.7)
19.3 (66.7)
26.7 (80.1)
27.3 (81.1)
34.7 (94.5)
35.3 (95.5)
RAC-10JH1, RAC-14JH1
DC 140 - 350V
40W
RED
BLK
0V
WHT
15V
YEL
BLU
WHT : WHITE
RED : RED
APPLICABLE MODELS
RAC-10JH1, RAC-14JH1
RAC-10JH1, RAC-14JH1
RAC-10JH1, RAC-14JH1
RAC-10JH1, RAC-14JH1
M

Advertisement

loading

This manual is also suitable for:

Rac-10jh1Ras-14jh1Rac-14jh1