Download Print this page

Advertisement

Available languages

Available languages

Quick Links

PE 4002
PONT ELEVATEUR 4 COLONNES 5T LEVAGE
AUXILIAIRE 3.5T
4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T
clas.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the PE 4002 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CLAS PE 4002

  • Page 1 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T clas.com...
  • Page 2: Table Of Contents

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T SOMMAIRE GARANTIE EXCLUSIONS DE GARANTIE Emballage, transport et stockage Manuel d’utilisation Description de l’élévateur Spécifications techniques Sécurité Installation Calibration Fonctionnement Entretien et maintenance Pannes Annexes...
  • Page 3: Garantie

    Contact : Vous pouvez nous joindre par mail à sav@clas.com ou bien au 04 79 72 92 80 ou encore vous rendre directement sur notre site clas.com Si vous avez changé d’avis concernant votre achat, veuillez retourner ce produit avant d’essayer de l’installer.
  • Page 4: Emballage, Transport Et Stockage

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T EMBALLAGE, TRANSPORT & STOCKAGE Emballage (Picture 1) Picture 1 Transport (Picture 2) Les emballages peuvent être soulevés et déplacés à l’aide de chariots élévateurs, de grues ou de ponts roulants. En cas d’élingage, afi n d’éviter toute manipulation dangereuse, une deuxième personne doit être présente pour s’assurer que la cargaison est manipulée en...
  • Page 5: Manuel D'utilisation

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T MANUEL D’UTILISATION Le manuel suivant est destiné aux opérateurs d’engins de levage expérimentés et spécialisés et au personnel technique responsable de l’installation et de la maintenance courante de l’installation. Il est recommandé au personnel participant aux tâches et opérations de levage du pont de levage de lire attentivement et complètement le «Manuel d’utilisation et d’entretien».
  • Page 6: Description De L'élévateur

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T DESCRIPTION DE L’ELEVATEUR Mode d’utilisation : Le pont est conçu pour soulever tout type de véhicule ayant une capacité de charge inférieure à 5000 kg (et de 3500kg pour le levage auxiliaire), et peut être utilisé pour les essais, l’entretien et la maintenance des véhicules.
  • Page 7: Spécifications Techniques

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T SPÉCIFICATIONS TECHNIQUES Principaux paramètres techniques Modèle Paramètres Transmission Electrohydraulique Capacité levage Capacité levage auxiliaire 3,5T Hauteur de levage 1890mm Hauteur levage auxiliaire 460mm Hauteur initiale de la plateforme 260mm Longueur...
  • Page 8 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Dimensions de l’élévateur (Picture 3): Moteur Pompe Modèle Y90L Type pump Puissance 2.2kw Modèle Tension AC 400 or 230V ±5% Débit maximal 4.3 cc(50Hz) / 3.2 cc(60Hz) Courant 400V: 5A 230V: 40A...
  • Page 9 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T SCHÉMA D’INSTALLATION Exigences : Béton de type 425#, la période de séchage est de 15 jours Épaisseur du béton ≥150mm, alignement sur toute la longueur ≤5mm. Attention 1. La tolérance maximale autorisée pour le niveau du sol est de 5 mm 2.
  • Page 10: Sécurité

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T SÉCURITÉ Il est recommandé de lire ce chapitre attentivement et complètement car il contient des informations importantes sur les règles de sécurité à adopter par l’opérateur et les autres utilisateurs même en cas d’utilisation incorrecte du pont élévateur.
  • Page 11 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T PRÉCAUTIONS GÉNÉRALES L’exploitant, l’installateur et le technicien de service doivent respecter les règles de sécurité en vigueur dans le pays où l’élévateur est installé. En outre, l’exploitant, l’installateur et le responsable de la maintenance doivent: •...
  • Page 12 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T RISQUES GÉNÉRAUX EN PHASE DE MONTÉE ET DE DESCENTE : Les dispositifs de sécurité suivants sont utilisés pour protéger contre les situations de surcharge et pour prévenir les pannes de moteur.
  • Page 13 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T RISQUE DE CHUTE – OPÉRATEURS Pendant la montée et la descente, le personnel n’est pas autorisé à monter sur les plates- formes et dans le véhicule pour éviter le danger de chute.
  • Page 14: Installation

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T INSTALLATION CES OPÉRATIONS NE DOIVENT ÊTRE EFFECTUÉES QUE PAR DU PERSONNEL AUTORISÉ ET COMPÉTENT, IL EST RECOMMANDÉ DE SUIVRE TOUTES LES INSTRUCTIONS CI- DESSOUS POUR ÉVITER D’ÉVENTUELS DOMMAGES À L’ÉLÉVATEUR OU DES RISQUES DE BLESSURES CORPORELLES.
  • Page 15 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Le poteau est fi xé à l’extrémité de la traverse et le bloc de nylon doit être maintenu à proximité. Le poteau principal (avec la station de pompage) est fi xé sur le côté gauche devant l’avancement du véhicule et les autres poteaux doivent être fi xés de manière à...
  • Page 16: Calibration

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Ajout d’huile hydraulique selon les instructions. Après avoir installé l’élévateur comme indiqué à la fi gure 4, en connectant le circuit hydraulique/ électrique et tout circuit pneumatique, procédez comme suit : •...
  • Page 17 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Réglage du cric roulant Si le pont est équipé d’un cric roulant manuel, Appuyez sur la poignée de la pompe manuelle pour lever la plate-forme à environ 300 mm. Détachez la poignée pour soulever la tige de sécurité du cric roulant et abaisser le cric.
  • Page 18: Fonctionnement

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Test à vide de la machine principale Mettre en marche l’«INTERRUPTEUR PRINCIPAL». QS. Appuyez sur le bouton «UP» SB1, les plateformes montent. Appuyez sur le bouton «DOWN» SB2, les plateformes montent un peu puis descendent.
  • Page 19 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T Instructions sur le fonctionnement électrique Placez le sélecteur du panneau de commande sur la position «MAIN LIFT». Lampe témoin Interrupteur principal Buzzer Interrupteur de commande pour la lumière LED (option) «HAUT»...
  • Page 20 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T ARRÊT D’URGENCE Appuyez sur le bouton «EMERGENCY STOP» SB0, pour couper tous les circuits de fonctionnement lorsque la machine est anormale. LOCK Lorsque vous appuyez sur le bouton «LOCK SEC. DOWN» lorsque les plateformes sont plus hautes que 300mm, le pont se verrouille ou descend un peu pour se verrouiller.
  • Page 21 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T OPÉRATION MANUELLE D’URGENCE POUR LA DESCENTE (PANNE DE COURANT) Lors de l’abaissement par opération manuelle, il faut observer l’état de la plate-forme à tout moment, car des véhicules se trouvent dessus.
  • Page 22: Pannes

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T PANNES SYMPTOMES CAUSES SOLUTIONS La connexion des fils d’alimentation ou du fil zéro n’est Vérifiez et corrigez la connexion des fils. pas correcte. Si le moteur fonctionne en forçant le contacteur vers le bas avec une tige d’isolation, vérifiez le...
  • Page 23: Annexes

    PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T ANNEXE SCHEMA HYDRAULIQUE 1. cylindre principal 8. soupape de contrôle du trop-plein 2. cylindre secondaire 9. pompe hydraulique 3. soupape antidétonante 10. moteur 4. soupape d’équilibrage 11. fi ltre 5. clapet anti-retour 12.
  • Page 24 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T ANNEXE SCHEMA RACCORDEMENT HUILE...
  • Page 25 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T ANNEXE SCHEMA ELECTRIQUE...
  • Page 26 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T SUMMARY WARRANTY WARNING INFORMATION PACKING, TRANSPORT & STORAGE INTRODUCTION DESCRIPTION OF THE LIFT SPECIFICATIONS SAFETY INSTALLATION ADJUSTMENT OPERATION CARE & MAINTENANCE TROUBLESHOOTING APPENDIX 46 -51...
  • Page 27: Warranty

    Contact : You can reach us by mail sav@clas.com or by phone +33(0)4 79 72 69 18 or go directly to our website clas.com If you have changed your mind regarding your purchase, please return this product before you attempt to install it.
  • Page 28: Packing, Transport & Storage

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T PACKING, TRANSPORT & STORAGE Packing (Picture 1) Picture 1 Transport (Picture 2) Transport (Picture 2) Packaging can be lifted or moved by lift trucks, cranes or overhead cranes. In case of slinging, a second person must always take care of the load, in order to avoid dangerous oscillations.
  • Page 29 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T MANUAL INTRODUCTIONS This manual has been prepared for those who are expert in the use of the lifters such as operators and technicians that are responsible for the installation and the routine maintenance.
  • Page 30: Description Of The Lift

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T DESCRIPTION OF THE LIFT How to use: The crane is designed to lift any type of vehicle with a load capacity of less than 5000kg (and 3500kg for auxiliary lifting), and can be used for testing, servicing and maintenance of vehicles.
  • Page 31: Specifications

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T SPECIFICATIONS Main technical parameters Model Paramètres Drive Electrical hydraulic Max lifting weight Max lifting auxilary lift 3,5T Lifting height 1890mm Auxilary height 460mm Platform initial height...
  • Page 32 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Lift dimension picture (Picture 3): Engine Pump Type Y90L Type gear pump Power 2.2kw Model Voltage AC 400 or 230V ±5% Flux 4.3 cc(50Hz) / 3.2 cc(60Hz)
  • Page 33 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Installation scheme for scissor lift: Concrete type 425#. Thickness of concrete≥150mm, the leveling of whole length ≤5mm. Picture 4 (installation drawing) Minimum concrete thickness and grading are the fundamental characteristics that must be...
  • Page 34: Safety

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T SAFETY It is recommended to read this chapter carefully and completely as it contains important information on the safety rules to be adopted by the operator and other users even in case of incorrect use of the elevator.
  • Page 35 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T GENERAL PRECAUTIONS The operator, installer and service technician must comply with the safety regulations in force in the country where the elevator is installed.
  • Page 36 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T GENERAL RISKS FOR LIFTING OR DESCENT The following safety devices are used to protect against overload situations and to prevent engine failure. In the event of an overload, the safety valve opens and discharges the oil directly to the tank (see fi gure 8).
  • Page 37 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T FALL HAZARD - OPERATORS During ascent and descent, personnel are not allowed to climb on the platforms and in the vehicle to avoid the danger of falling.
  • Page 38: Installation

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T INSTALLATION THESE OPERATIONS SHOULD ONLY BE PERFORMED BY AUTHORIZED AND COMPETENT PERSONNEL, IT IS RECOMMENDED TO FOLLOW ALL INSTRUCTIONS BELOW TO AVOID POSSIBLE DAMAGE TO THE ELEVATOR OR RISK OF PERSONAL INJURY.
  • Page 39 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Rolling Cylinder Installation (optional part): -Adjust the distance of the rolling cylinder; place the rolling cylinder between the slide rails. Adjust the sub-beam to ensure the bearing jack slides.
  • Page 40: Adjustment

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Add hydraulic oil according to instructions. After installing the elevator as shown in Figure 4, connecting the hydraulic/electrical system and any pneumatic system, proceed as follows: •...
  • Page 41 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Adjustment of the jack If the crane is equipped with a manual jack, Press the handle on the hand pump to raise the platform to approximately 300 mm.
  • Page 42: Operation

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T No-load test of the main machine Switch on the «MAIN SWITCH». QS. Press the «UP» button SB1, the platforms go up. Press the «DOWN» button SB2, the platforms go up a little and then go down.
  • Page 43 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Instructions on electric operation Turn the seletor switch on the control panel to the «MAIN LIFT» position. LIFTING Press the «UP» button SB1, the oil pump runs and the platform rises. The machine stops lifting when it touches the lift limit switch.
  • Page 44 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T EMERGENCY STOP Press the «EMERGENCY STOP» button SB0, to turn off all operating circuits when the machine is abnormal. LOCK When you press the «LOCK SEC. DOWN» button when the platforms are higher than 300mm, the deck will lock or lower a little to lock.
  • Page 45 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T EMERGENCY MANUAL OPERATION FOR LOWERING (POWER FAILURE) When lowering by manual operation, observe the condition of the platform at all times, because there are vehicles on it.
  • Page 46: Troubleshooting

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T TROUBLESHOOTING FAILURE CAUSE TROUBLESHOOTING The connection of the power wires or the zero wire is not Check and correct wire connection. correct. If the motor operates by forcing the contactor...
  • Page 47: Appendix

    PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T APPENDIX HYDRAULIC SCHEMA 1. main cylinder 8. overfl ow control valve 2. sub cylinder 9. gear pump 3. anti-knok valve 10. pump motor 4. mending balance valve 11.
  • Page 48 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T APPENDIX OIL PIPE CONNECTION DIAGRAM...
  • Page 49 PE 4002 PE 6001 DOUBLE SCISSOR LIFT 3T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T APPENDIX CIRCUIT DIAGRAM...
  • Page 50 Philippe Barrault, 25.10.2021 CLAS EQUIPEMENTS - SAS au capital de 130 000€, R.C.S Chambéry : 409 786 944, N° TVA Intracommunautaire FR 13 409 786 944 Siège social, Z.A de la Crouza – 73800 CHIGNIN - FRANCE +33 (0)4 79 72 62 22 -  +33 (0)4 79 72 52 86 ...
  • Page 52 FRANCE Tél. +33 (0)4 79 72 62 22 Fax. +33 (0)4 79 72 52 86 PE 4002 PONT ELEVATEUR 4 COLONNES 5T LEVAGE AUXILIAIRE 3.5T 4 COLUMNS POST LIFT 5T AUXILIARY LIFT 3.5T Si vous avez besoin de composants ou de pièces, contactez le revendeur En cas de problème veuillez contacter le technicien de votre distributeur agréé...