Page 1
Solax Power Network Technology(Zhe jiang) Co,. Ltd. Copyright Declaration The copyright of this manual belongs to Solax Power Network Technology(Zhe jiang) Co,. Ltd. Any corporation or individual should not plagiarize, partitially or fully copy (including software,etc.), and no reproduction or distribution of it in any form or by any means. All rights reserved. SolaX Power Network Technology (Zhe jiang) Co.,Ltd.
Contents Note on this Manual CABLE CONNECTION......................Scope of Validity 4.5.1 CONNECTING POWER CABLES..................This manual is an integral part of T-BAT Series. It describes the assembly, 4.5.2 CONNECTING RS485 COMMUNICATION CABLE..........installation, commissioning, maintenance and failure of the product. Please read 4.5.3 CONNECTING CAN COMMUNICATION CABLE..........
Max.Short-circuit Current:693A (Duration:1.77ms) Risks of fire Ÿ SolaX Power Network Technology (Zhejiang) Co., Ltd ADD: No.288 Shizhu Road, Tonglu Economic Development Zone, Dongxing District, Tonglu City, Zhejiang Province, China. Made in China – Do not expose the battery module to temperatures in excess of 60°C.
Response to Emergency Situations Symbol Explanation 2.2.1 Leaking Batteries If the battery leaks electrolyte which is corrosive, avoid contact with the leaking liquid or gas. Direct contact may lead to skin irritation or chemical burns. If one is exposed to the leaked substance, do these actions: TUV mark for IEC62619 Accidental inhalation of harmful substances:Evacuate people from the contaminated area , and seek medical attention immediately.
3. Product Introduction Product Introduction Qualified Installer Product Overview Triple power battery is a series of High Voltage Lithium-ion battery. It is designed WARNING! for residential and commercial energy storage system. All operations of T-BAT SYS-HV relating to electrical connection and installation must be carried out by qualified personnel.
The T-BAT SYS-HV is one of the advanced energy storage systems on the market Model Battery Module Energy(kWh) Voltage (V) today, incorporating state-of-the-art technology, high reliability, and convenient MC0500x1 control features shown as below: T-BAT H4.5 HV10045X1 85-118 MC0500x1 90% DOD Ÿ...
4. Installation 4. Installation Installation Tools These tools are required to install the T-BAT system. Installation Prerequisites Make sure that the installation location meets the following conditions: The building is designed with resistance to earthquakes Ÿ Torque Screwdriver Phillips Screwdriver Hexagon Wrench The location is far away from the sea, to avoid sea water and humid air Ÿ...
4. Installation 4. Installation 4.4.4 Install BMS to Battery Module 4.4.5 Mounting Steps Place the BMS on top of the battery module and affix it with M5 screws (M) It is recommended that the space between battery modules is more than using an L-type wrench (I).
4. Installation 4. Installation 2. After all the battery modules are correctly connected, plug the short-circuit 4.5.2 Connecting RS485 Communication Cable plug (F) at YPLUG (Ⅴ’) of last battery module to make a complete circuit. For one battery module: 1. There is a protective cap for the RS485 connector, unscrew the cap and plug one end of the RS485 communication cable to the RS485 connector on BMS.
4. Installation 4. Installation 4.5.3 Connecting CAN Communication Cable 4.5.4 Connecting Ground Wire It is required for the BMS to communicate with the inverter for proper operation. For one battery module: Unscrew the ground terminal with hexagon wrench on BMS and battery module at either side of the ground port as marked at the following figue.
Page 16
4. Installation 4. Installation Ø Connecting Battery Power Cables between Inverter and BMS: 4.5.5 Connecting Battery Power Cables This step is to connect battery power cables between Inverter and T-BAT system. 1. Connect the battery power cables between Inverter and BMS. Please pay attention to connect the cables (+,-) to the correct BAT port on both the Inverter and BMS.
4. Installation 5. Commissioning Overview of Installation Commissioning The following diagram is a complete T-BAT system installation with four battery Configuring Battery System modules. The DIP switch is used to configure the number of battery modules which are communicating to Inverter. The detailed configuration information is shown as follows: Configuration activated by inverters Matching one battery module (default)
Page 18
5. Commissioning 5. Commissioning Commissioning Verify the model number of each battery module to make sure that they are all NOTE! the same model. When powering on the BMS, the system will start self-testing. If the buzzer If all the battery modules are installed, follow these steps to put it in operation. beeps, it means the DIP configuration is in fault or communication failure has 1.
5. Commissioning 5. Commissioning 5.3.2 Battery Module (T45/T63) Status Indicators The LED indicators on the front panel of the BMS and battery modules are showing the operating status. 5.3.1 BMS (Master Box) S1 and S2 represent independent status indicators. The status of S1 and S2 have the same meaning for battery module in the following table.
6. Troubleshooting 6. Troubleshooting Troubleshooting Warning Messages Description Troubleshooting Troubleshooting Wait till the temperature of cells go Battery over BMS_TemHigh Check the indicators on the front to determine the state of the T-BAT system. A temperature back to the normal state. warning state is triggered when a condition, such as voltage or temperature, is beyond design limitations.
8. Maintenance 7. Decommissioning Decommissioning Maintenance Dismantling the Battery If the ambient temperature for storage is -20~55°C, recharge the batteries Shutting down T-BAT system at least one time every 3 months. Disconnect the cables between BMS and inverter If the ambient temperature for storage is -20~20°C, recharge the batteries Disconnect the short-circuit plug on the last battery module at least one time every 6 months.
9. Disclaimer Disclaimer SolaX protects this product under warranty when it is installed and used as listed in this manual. Violation of installation procedure or use of the product in any way not described in this manual will immediately void all warranties on the product.
Need help?
Do you have a question about the T-BAT H4.5 and is the answer not in the manual?