Equired Learances; Earth Rotection - Lennox Hearth Products Legacy C260 Installation And Operation Manual

Pa certified wood-burning fireplace inserts
Table of Contents

Advertisement

r
c
equired
learances
WARNING: BE ABSOLUTELY SURE THE DISTANCE BE-
TWEEN THE HEATER AND THE SURFACE OF ANY COM-
BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN
ON THIS PAGE.
Model
*A
C260
30"
762mm
E260
23"
584mm
C260 with mantel
30"
762mm
and/or side
shields
u
Model
F (1)
C260
22"
559mm
E260
22"
559mm
C260 with mantel
22"
559mm
and/or side
u
shields
* Reduced clearances may be available for A, B, C and D
dimensions per NFPA 211 - latest edition, Standard for
Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli-
ances (in Canada CSA B365 - latest edition). See section on
"Reduction of Appliance Clearance with Specified Forms of
Protection."
** Side view of optional mantel deflector shown.
uElite™ E260 - Not tested for reduction of clearances
(1)Hearth extension reductions: 2" (51mm) reduction for 2"
(51mm) raised hearth. (USA) 16" minimum hearth exten-
sion on all stoves as measured from the door opening of the
unit. (Canada) 18"(450mm) minimum hearth extension on
all stoves as measured from the door opening of the unit.
Minimum distance of floor protection to the side = 8" (200mm).
This is measured from the sides of the door opening in the
USA and from the sides of the insert in Canada.
H
P
eartH
rotection
The hearth and/or floor protection must be a thermally rated
non-combustible hearth/floor protector meeting or exceeding
a thermal rating of k=.84 or equivalent with a listed thickness
of listed thickness of 3/4" (19mm) minimum in the USA and
Canada. The covering must extend USA-16"/Canada-18"
(C260) and 22" (E260) in front of the heater and 8" to the
side (measured from door opening in the USA and measured
from the side of the unit in Canada).
*B
*C
*D
20"
20"
15"
200mm
508mm
508mm
381mm
1"
20"
15"
200mm
432mm
508mm
381mm
20"
20"
15"
200mm
508mm
508mm
381mm
G
H
J
14"
22-1/2"
5-1/4"
356mm
572mm
133mm
14"
22-1/2"
5-3/4"
356mm
572mm
133mm
14"
22-1/2"
5-1/4"
356mm
572mm
133mm
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Top Facing / Trim
E(1)
8"
8"
C
8"
E (USA)
M
Figure 4
50-1/2"
1283mm
45"
1143mm
38"
965mm
M
Figure 5
Notes
• Facing material that projects more than 3/4" (19mm) from
the wall is considered a mantel or side wall.
• MINIMUM FIREPLACE OPENING 22-1/2" (52mm) High x
28-1/2" (24mm)
Maximum Mantel Depth = 9" (229 mm)
COMBUSTIBLE MANTEL
A
B
D
Insert
Hearth Protection
Mantel
Trim
**
6-1/2"
165mm
F
Hearth Protection
E
(Canada)
G
J
H


Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite e260

Table of Contents