Equired Learances - Lennox Hearth Products Performer CA210 Installation And Operation Manual

Epa certified wood-burning fireplace inserts
Table of Contents

Advertisement

r
C
equireD
learanCes
WARNING: BE ABSOLUTELY SURE THE DISTANCE BE-
TWEEN THE HEATER AND THE SURFACE OF ANY COM-
BUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN
ON THIS PAGE.
Model
*A
C/A210
USA-24"
USA -18"
CAN-813mm
CAN-660mm
C/A210 w/
USA-16"
USA -10"
CAN-813mm
CAN-660mm
mantel
and/or side
shields
u
Model
F (1)
C/A210
18"
450mm
C/A210 w/
18"
450mm
mantel and/or
u
side shields
* Reduced clearances may be available for A, B, C and D
dimensions per NFPA 211 - latest edition, Standard for
Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Ap-
pliances (in Canada CSA B365 - latest edition). See section
on "Reduction of Appliance Clearance with Specified Forms
of Protection."
** Side view of optional mantel deflector shown.
(1)Hearth extension reductions: 2" (51mm) reduction for 2"
(51mm) raised hearth. (USA) 16" minimum hearth exten-
sion on all stoves as measured from the door opening of the
unit. (Canada) 18"(450mm) minimum hearth extension on
all stoves as measured from the door opening of the unit.
Minimum distance of floor protection to the side = 8" (200mm).
This is measured from the sides of the door opening in the
USA and from the sides of the insert in Canada.
(2) J = Maximum lintel depth without flue offset or smoke
deflector.
h
P
earth
roteCtion
The hearth and/or floor protection must be a thermally rated
non-combustible hearth/floor protector meeting or exceeding
a thermal rating of k=.84 or equivalent with a listed thickness
of 3/8" (9.5mm) minimum in USA (3/4" - 19mm minimum in
Canada). The covering must extend 18" (450mm) in front
of the heater and 8" (200mm) to either side (measured from
door opening in the USA and measured from the side of the
unit in Canada).
Notes:
• Facing material that projects more than 3/4" (19mm) from
the wall is considered a mantel or side wall.
• MINIMUM FIREPLACE OPENING 19-1/2" (495mm) High x
26" (660mm) Wide
*B
*C
*D
18"
15"
USA-8"
450mm
381mm
CAN-200mm
18"
USA-8"
USA-8"
450mm
381mm
CAN-200mm
G
H
J(2)
12-1/4"
19"
4-1/2"
311mm
483mm
114mm
12-1/4"
19"
4-1/2"
311mm
483mm
114mm
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Top Facing / Trim
E(1)
C
M
E (USA)
42-1/8"
Figure 4
1070mm
34-1/8"
867mm
M
Figure 5
Figure 6
Maximum Mantel Depth = 9" (229 mm)
COMBUSTIBLE MANTEL
A
B
D
Insert
Hearth Protection
Mantel
Trim
**
9"
6-1/2"
165mm
229mm
F
Hearth Protection
Top View
23"
584mm
25-1/2"
648mm
E
(Canada)
G
J
H


Advertisement