Levelling the product
The product must be level for proper operation.
In the DFH model, level by adjusting the two front feet and the central levelling
foot.
-
Loosen the locknut (B).
-
Screw or unscrew the two front feet (A) until the frame is in a stable
position.
-
Tighten the locknut (B) on the two front feet. At this stage, the central
levelling foot (C) SHOULD NOT be touching the floor.
-
Unscrew the central levelling foot (C) until it touches the floor.
-
Tighten the locknut (B) on the central levelling foot.
In the DF5 model, level by adjusting the two front feet. There is no central
levelling foot (C) on this model.
-
Loosen the locknut (B).
-
Screw or unscrew the two front feet (A) until the frame is in a stable
position.
-
After adjusting, tighten the locknut (B).
SYNCHRO EXCITE LIVE
A
A
19
C
B