Njoy Echo Pro Series User Manual

Njoy Echo Pro Series User Manual

Sensor box (temperature & humidity)
Hide thumbs Also See for Echo Pro Series:

Advertisement

Quick Links

Sensor Box (Temperature & Humidity)
UPAC-TEMPHUM-CG01B
User manual
111.0
Before using this product, carefully read all product documentation and retain it for future reference.

Advertisement

loading

Summary of Contents for Njoy Echo Pro Series

  • Page 1 Sensor Box (Temperature & Humidity) UPAC-TEMPHUM-CG01B User manual 111.0 Before using this product, carefully read all product documentation and retain it for future reference.
  • Page 2: Table Of Contents

    5.1 FCC Warning ....................8 6. Troubleshooting ......................9 7. Appendix ......................... 10 nJoy UPS models that are compatible with this product: 7.1 Input Dry Contact Application ..............10 Echo Pro Series 1K / 2K / 3K...
  • Page 3: Product Overview

    Product overview Technical Specifications The environmental monitoring sensor (EMS-U01) along with selected Power EMS-U01 Management Cards (PMCARD) enables users to monitor the temperature and humidity of a server closet and/or data center remotely. Additionally, the Input Voltage 7V - 28V EMS-U01 provides 4 input dry contacts that enable users to monitor the sta- Halt mode 72 mW/ tus of connected devices, such as door switch sensors.
  • Page 4: Installation Guide

    4.2. Method 2: Fixed Mounting Installation Guide Step 1.  Drill a hole that is compatible with the anchor and insert the includ- ed anchor. 4.1. Method 1: Hook and Loop Step 2.  Insert and tighten the screw into the anchor. Leave enough of the Tape Mounting screw exposed for the sensor to be mounted to.
  • Page 5: Conformance Approvals

    Step 4.  To connect the sensor with PMCARD, use the attached RJ45 Ether- installation. If this equipment does not cause harmful interference to radio net Cable. Plug one end into the RJ45 Port and the other end into or television reception, which can be determined by turning the equipment the PMCARD.
  • Page 6: Appendix

    Appendix 7.1. Input Dry Contact Application Do not input signals that carry voltage into the input dry contacts. The input dry contacts only allow for open/short circuit. Dry Contact Disposal of Old Electrical & Electronic Equipment (Applicable in the European Union and other European countries with separate collection systems) External Sensor 1/2/3/4 This symbol on the product or on its packaging indicates that this product shall...