ZXMW NR8120A/8120D Maintenance Guide
Parameter
Interval
Transmit Type
Performance Test
RMEP ID
Require Times
TST Transmit Rate
TST Packet Length
TST Test Time
3. In the left navigation tree, select ETH > OAM_CFM > Loopback. The CFM Loopback
pane is displayed on the right.
4. Set the parameters, and click the Apply button. The CFM loopback function is
enabled, see
Figure 3-5 CFM Loopback Pane
For a description of the parameters, refer to the following table.
SJ-20150804150350-006|2015-09-17 (R1.0)
Description
Sets the interval between sending functional packets. If Operator
Type is set to Test Transmission or Test Reception, this parameter
becomes unavailable.
Sets the packet transmit type to be Unicast or Multicast.
Sets whether the function is enabled.
Sets the remote MEP ID.
Sets the number of times that a functional packet is transmitted. If
Operator Type is set to Test Transmission or Test Reception, this
parameter becomes unavailable.
Sets the packet transmitting rate. This parameter is valid only when
the Operator Type parameter is set to Test Transmission or Test
Reception.
Sets the packet length. This parameter is valid only when the Operator
Type parameter is set to Test Transmission or Test Reception.
Sets the test duration. This parameter is valid only when the Operator
Type parameter is set to Test Transmission or Test Reception.