4.1 Using the Control Buttons

It is possible to perform basic maintenance functions on the Sensepoint
XCL gas detector without the use of the mobile app. This is achieved
through the use of two control buttons inside the detector. Familiarize
yourself fully on the operation of these buttons before attempting to
use them.
To inhibit the detector output: Press and hold the UP button for 2
seconds.
To increase the output voltage: Briefly press the UP button. Pressing
once increases by 0.01 V. To increase by 0.1 V, press and hold the button.
To decrease the output voltage: Briefly press the DOWN button.
Pressing once decreases by 0.01 V. To decrease by 0.1 V, press and hold
the button.
To move to the next stage: Press and hold the UP button for 2 seconds.
If a change has been made, it is saved automatically before proceeding
to the next stage.