Use The Product - Fluke C9970 User Manual

Voltage detector
Hide thumbs Also See for C9970:
Table of Contents

Advertisement

C9970
Users Guide
Test Plug Threshold Test
To do a test plug threshold test:
1. Do a self check test. See Self Check Test.
2. Use an ohmmeter to verify the integrity of the Plug. The resistance from the
test point to either or both of the two prongs should be 300 KW ±1 %. Do not
use a faulty test plug.
3. Insert the Plug into a standard, 3-wire, 110 V ac to 120 V ac outlet. The Plug
provides the proper reference voltage for the threshold test.
4. Touch the Product to the screw head test point on the Plug. The Product
passes the test if the red LED flashes to indicate the Product detects
dangerous voltage. The Product fails the test If the green LED emits light.

Use the Product

To use the Product:
1. Do a self check. See Self Check Test.
2. Remove the conductive end cap from the probe tip. Do not unscrew the front
and rear housing while removing the cap.
3. Hold the rear housing with your bare hand (except when gloves are required),
and use your thumb to operate the trigger. See Figure 3.
8
Figure 2. Self Check Test