Go Direct Fluorescence/UV-VIS Spectrophotometer is a small, lightweight
ultraviolet and visible light spectrofluorometer. It is a combined fluorometer with
a UV-VIS absorbance spectrometer. Exchangeable LEDs ensure you get the exact
excitation wavelength needed.
Note: Vernier products are designed for educational use. Our products are not
designed nor are they recommended for any industrial, medical, or commercial
process such as life support, patient diagnosis, control of a manufacturing
process, or industrial testing of any kind.
What's Included
Go Direct Fluorescence/UV-VIS Spectrophotometer
l
AC Power Supply
l
Fluorescence quartz cuvette
l
Mini USB cable
l
USB Power Adapter
l
LED cartridges (3): 375 nm, 450 nm, 525 nm
l
Compatible Software and Interfaces
See
www.vernier.com/manuals/gdx-spec-fuv
compatible with Go Direct Fluorescence/UV-VIS Spectrophotometer.
Getting Started
Please see the following link for platform-specific connection information:
www.vernier.com/start/gdx-spec-fuv
Bluetooth Connection
1. Install Vernier Spectral Analysis
your computer, Chromebook™, or
mobile device. See
www.vernier.com/spectral-analysis
for Spectral Analysis availability.
2. Connect the AC Power Supply to the
spectrophotometer. This supplies
power to the lamp. Turn the power
switch to the ON position. Wait for
the lamp indicator LED to remain
green.
®
3. To power the Bluetooth
radio,
connect the spectrometer to the USB
for a list of interfaces and software
USB Connection
®
on
1. Connect the AC Power Supply to
the spectrophotometer. Turn the
power switch to the ON position.
Wait for the lamp indicator LED to
remain green. Connect the
spectrometer to the USB port.
2. Launch the software. Options
include
Computer: Spectral Analysis or
l
Logger Pro 3
Chromebook: Spectral Analysis
l
LabQuest 2 or 3: LabQuest App
l
power adapter or to a powered USB
hub. The Bluetooth LED will blink.
Note: Do not plug the USB into a
computer USB port to run with
Bluetooth wireless technology.
4. Launch Spectral Analysis.
5. Click or tap Connect a Spectrometer.
Select your Go Direct
Fluorescence/UV-VIS
Spectrophotometer from the list of
Discovered Wireless Devices. Your
spectrometer's ID is located near the
barcode on the label. The Bluetooth
LED on the sensor will now glow
blue (no longer flashing).
6. Click or tap Done to enter data-
collection mode. You are now ready
to continue your experiment.
Powering the Spectrometer
Turning on the
Connect to AC power. Turn the power switch on. Green LED
spectrometer
indicator next to Power icon is solid when unit is ready to use.
If indicator light turns red, disconnect all power, wait one full
minute, and attempt again.
Turning off
Turn the power switch to the off position. The lamp will turn
the
off and the fan will continue to run to cool the electronics for
spectrometer
several more minutes. Wait until this is complete before dis-
connecting AC power.
Connecting the Spectrometer
See the following link for up-to-date connection information:
www.vernier.com/start/gdx-spec-fuv
Connecting via Bluetooth
Ready to connect
Connected
1
Mobile Device: Spectral Analysis
l
3. The software will identify the
spectrometer and enter data-
collection mode. You are now
ready to continue your experiment.
Note: This sensor does not work with
the original LabQuest. It works via
USB with LabQuest 2 or LabQuest 3.
Connect to AC power. Turn the power switch on.
To power the Bluetooth radio, connect the spec-
trometer to the USB power adapter or to a
powered USB hub. Blue LED next to Bluetooth
icon flashes when sensor is ready to connect.
Blue LED next to Bluetooth icon is solid when
sensor is connected via Bluetooth wireless tech-
nology.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Go Direct GDX-SPEC-FUV and is the answer not in the manual?

Questions and answers

Summary of Contents for Vernier Go Direct GDX-SPEC-FUV

  • Page 1 Discovered Wireless Devices. Your spectrometer's ID is located near the Note: Vernier products are designed for educational use. Our products are not barcode on the label. The Bluetooth designed nor are they recommended for any industrial, medical, or commercial...
  • Page 2: Using The Product With Spectral Analysis

    LED or a gas discharge tube. To do so, you will need to 7. To see the best fit line equation for the standard solutions, click or tap Graph purchase the Vernier Optical Fiber (order code: VSP-FIBER). Tools, select Apply Curve Fit, and choose Linear. Click or tap Apply.
  • Page 3 Fluorescence, follow tap OK. the instructions in the Spectral Analysis user manual at www.vernier.com/spectral- . Note: You may need to change the integration time to get accurate peak Collect Data with LabQuest analysis intensities in fluorescence mode.
  • Page 4 Measurement vs. Concentration (Beer’s Law Studies) concentration, and fluorescence vs. time for kinetics experiments. Once the units 1. Generate a spectrum as described above. On the Meter screen, tap Mode. have been changed to Fluorescence from the Experiment menu, follow the Change the mode to Events with Entry.
  • Page 5: Using The Product With Logger Pro

    To increase the sample time, or if data collection is unusually slow, choose Set Up 3. Follow the instructions in the dialog box to complete the calibration, and then Sensors ► Spectrophotometer: 1 from the Experiment menu. Set the Sample Time click (begin with 75 ms, with subsequent reductions by 20 ms) to a suitable value and Collect Data with Logger Pro...
  • Page 6 Option 1 The default option is to use a single 10 nm band. This measures emission of light by a compound after it has absorbed a particular wavelength of the average absorbance from ~5 nm on either side of the chosen light.
  • Page 7: Specifications

    This instrument contains an internal high-voltage power source. Position the instrument where the ON/OFF switch can be easily reached. Do not move the Videos instrument when it is running. Do not attempt to open or remove the case at View videos related to this product at www.vernier.com/gdx-spec-fuv any time.
  • Page 8: Troubleshooting

    Replacement Power Supply for Ultraviolet VSP-UV-PS Range (UV-VIS) Spectrophotometers Do not use this instrument if it is damaged in any way. Contact Vernier Technical Support for troubleshooting and technical assistance. Warranty Do not use this instrument for clinical or diagnostic procedures.
  • Page 9 • www.vernier.com Rev. 1/20/2022 Go Direct, Vernier Spectral Analysis, Logger Pro,, Vernier LabQuest, and other marks shown are our trademarks or registered trademarks in the United States. iPad is a trademark of Apple Inc., registered in the U.S. and other countries.

Table of Contents