Datalogic PWR-120 Installation Manual
Hide thumbs Also See for PWR-120:

Advertisement

Quick Links

> PWR-120

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PWR-120

  • Page 1 > PWR-120...
  • Page 2 PWR-120 Installation Manual Ed.: 06/2017 © 2002 – 2017 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A.
  • Page 3: Table Of Contents

    System Wiring: Test ...................... 1  2  INSTALLATION ......................2  2.1  Cabinet Mounting ......................2  2.2  PWR-120 Electrical Diagram ..................3  2.3  Cable Insertion ......................4  2.3.1  Compression Connectors ..................... 4  2.3.2  Installing the AS-I Cable ....................4  3  ELECTRICAL CONNECTIONS ................... 5 ...
  • Page 4: Safety Regulations

    SAFETY REGULATIONS ELECTRICAL SAFETY This product conforms to the applicable requirements contained in the European Standard for electrical safety EN 60950-1 at the date of manufacture. WARNINGS or CAUTIONS: This symbol identifies a hazard or procedure that, if incorrectly performed, could cause personal injury or result in equipment damage.
  • Page 5: Ce Compliance

    SUPPORT THROUGH THE WEBSITE Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the SUPPORT > Unattended Scanning Systems category link.
  • Page 6: General View

    GENERAL VIEW Key Lock Safety Fuse Compression Connectors AC Socket (for use only during maintenance) AS-I Cable Sealing Grommet AC Line Input Terminal Block Monophase Switching Power Supply 24 Vdc Terminal Block Product Data Label Figure 2 – PWR-120 General View...
  • Page 7: Guide To Installation

    GUIDE TO INSTALLATION 1 GUIDE TO INSTALLATION The following can be used as a checklist to verify all the steps necessary to complete installation of the PWR power Supply. CAUTION: Before opening the device, or performing any installation or maintenance procedures, make sure the external AC disconnecting device is switched OFF.
  • Page 8: Installation

    PWR-120 INSTALLATION MANUAL 2 INSTALLATION The PWR-120 is an industrial cabinet housing a 24 Vdc power supply which is used to power up a varying number of reading devices (depending on the product), along with their relative accessory devices. See chapter 3 for details.
  • Page 9: Pwr-120 Electrical Diagram

    INSTALLATION 2.2 PWR-120 ELECTRICAL DIAGRAM The PWR-120 components are electrically connected as displayed in the following diagram: Two-Pole Disconnecting Switch Fused 2A * AC Socket Monophase Switching Power Supply 5A max. 24 Vdc Figure 3 - PWR-120 Electrical Diagram CAUTIONS: * The AC socket is connected directly to the AC line and must...
  • Page 10: Cable Insertion

    2.3.1 Compression Connectors Follow these instructions to correctly insert the cables: Determine the number and size of the cables coming into and leaving the PWR-120. Locate the correct compression connector sizes and positions relative to these cables. Pass the cable end through the proper compression connector so that the gland material seals around it when tightened.
  • Page 11: Electrical Connections

    ELECTRICAL CONNECTIONS 3 ELECTRICAL CONNECTIONS The PWR-120 power unit provides a terminal block through which AC Line voltage enters and 24 Vdc Low Voltage output is provided. Figure 4 - Terminal Block...
  • Page 12: Input Ac Line Voltage

    Wire according to the following points: Primary wiring: Overcurrent protection should be provided by a 16 A building installation circuit breaker. Wiring methods from the branch circuit breaker to the PWR-120 power supply shall comply with the National Electric Code ANSI\NFPA.
  • Page 13: Laser Barcode Scanners

    The power supply unit is connected directly to the scanners via AS-I cabling. AC in 24 Vdc to scanners using AS-I cabling with end cap Figure 6 - Connecting PWR-120 to AS-I Compatible Scanners Refer to the specific scanner manual for I/O interface wiring connections.
  • Page 14: Supply Capacity When Wiring Directly To Lonworks Scanners

    However all the scanner motors start up slowly so that there is no significant peak current draw. See the specific scanner manual for consumption data. The maximum number of scanners to be supplied for direct wiring by a single PWR-120 is shown in the table below:...
  • Page 15: Image-Based Id Readers

    ELECTRICAL CONNECTIONS 3.3 IMAGE-BASED ID READERS 3.3.1 Supply Capacity When Wiring to XRF410N Readers The maximum number of XRF410N modules to be supplied by a single PWR-120 is shown in the following table. Maximum Number of Modules XRF410N Model Base (Bxx)
  • Page 16 Master Terminator AC in Custom Cable CBL-1480-05 CBX500 ATS-001 CAB-DS05-S P.S. Ethernet Host Figure 9 - Connecting PWR-120 to an XRF410N Hi Perf Module Custom Power Cable to CBX CAB-MLP-0x Cable PWR-120 Wire Color Meaning 24 V+ White 24 V+...
  • Page 17: Supply Capacity When Wiring To Matrix 450N Readers

    The Matrix M450N uses the CAB-LD-102 no power cable CAB-MS0x between the reader and its relative LT-03x illuminator. Figure 10 - Connecting PWR-120 to a Matrix 450N Custom Power Cable to CBX CAB-LP-0x Cable to LT-03x PWR-120 Wire Color Meaning...
  • Page 18: Technical Features

    PWR-120 INSTALLATION MANUAL 4 TECHNICAL FEATURES ELECTRICAL FEATURES Input Voltage AC from 100 to 240 V from 50 to 60 Hz Input Current Consumption Max. 6.6 A (Max. 1.6 A for power supply – output at full load) (Max. 5 A for internal AC socket) Output Voltage 24 Vdc (adjustable 18-29.5 Vdc)