PWR-120 INSTALLATION MANUAL Reading Station Power Supply...
Page 2
Electronic versions of this document may be downloaded from the Datalogic website (www.datalogic.com). If you visit our website and would like to make comments or suggestions about this or other Datalogic pub- lications, please let us know via the "Contact" page.
Supply Capacity When Wiring to Matrix 450N Readers ..............12 CHAPTER 5. AC LINE VOLTAGE ELECTRICAL CONNECTIONS ........13 AC Line Input Voltage ..................... 13 CHAPTER 6. TECHNICAL FEATURES ............... 15 APPENDIX A. ELECTRICAL DIAGRAMS ..............16 PWR-120 Electrical Diagram ..................16 INSTALLATION MANUAL...
SAFETY REGULATIONS Electrical Safety This product conforms to the applicable requirements contained in the following Euro- pean Standards: • EN 61439-1 • EN 60204-1 • EN 60950-1 +A11 +A1 +A12 +A2 • EN 62368-1 PWR-120...
TECHNICAL SUPPORT Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to (www.datalogic.com). For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for.
OPERATING FEATURES DESCRIPTION The PWR-120 is an electrical cabinet housing a 24 Vdc power supply which is used to power up a varying number of reading devices (depending on the product), along with their relative accessory devices. See “LOW Voltage Electrical Connections” on page 6 for details.
Figure 4 Short-Circuit Protection HICCUP Mode. For this condition, the maximum length of the power cables between the power supply and the powered devices guarantees the behavior of a short-circuit downstream of this cable. Figure 2 - Short Circuit Protection HICCUP Mode PWR-120...
CHAPTER 2 PRE-INSTALLATION CHECKLIST This chapter can be used as a checklist to verify all the steps necessary to complete installation of the PWR power Supply. HIGH VOLTAGE: Opening the cabinet requires a key that should be used by a person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and avoid hazards which electricity can create.
PWR powers up correctly. The green DC-OK light should be on steady and the overload light (red) should off. 7. Close and lock the PWR enclosure and check that it does not open (lock functions correctly). The PWR-120 installation is now complete. PWR-120...
The cabinet must be installed vertically in such a way that the key lock is not higher than 1.90 m from the ground. NOTE Figure 2 - PWR-120 cabinet max. height Please note that the cabinet door can be unlocked and opened by using the key pro- vided along with the product.
3. Pass the cable end through the proper compression connector so that the gland material seals around it when tightened. There are three compression connector sizes with the following specifications: NUMBER OF COMPRESSION CABLE DIAMETER CONNECTORS Millimeters Inches 9-14 0.354-0.551 3.5-8 0.138-0.315 7-13 0.256-0.512 PWR-120...
DC LOW VOLTAGE CABLE INSERTION Installing the AS-I Cable Prepare the AS-I cable by first inserting the compression connector nut, then the AS-I cable sealing grommet onto the AS-I cable. Then strip the outer protection sheath leav- ing about 5 cm of blue and brown wires free for positioning. Strip the individual wires for insertion into the Terminal Block.
DC VOLTAGE TERMINAL BLOCK DC OK Signals DC Outputs Figure 2 - PWR-120 DC Output Power Connections DC OK Monitoring The DC voltage terminal block provides two wiring terminals (13-14), which monitor the status of the switching power supply (DC OK feature). When the power supply module runs correctly, lines 13 and 14 form a normally closed contact.
The power supply unit is connected directly to the scanners via AS-I cabling. AC in 24 Vdc to scanners using AS-I cabing with end cap Figure 3 - Connecting PWR-120 to AS-I Compatible Scanners Refer to the specific scanner manual for I/O interface wiring connections. INSTALLATION MANUAL...
LOW VOLTAGE ELECTRICAL CONNECTIONS IMAGE-BASED ID READERS Supply Capacity When Wiring to XRF410N Readers The maximum number of XRF410N modules to be supplied by a single PWR-120 is shown in the following table. MAXIMUM NUMBER OF XRF410N MODEL MODULES Base (Bxx)
Page 17
24 Vdc CAB-MLP-05 AC in Custom cable CBL-1480-05 CBX500 ATS-001 CAB-DS05-S P.S. Ethernet Host Figure 5 - Connecting PWR-120 to an XRF410N Hi Perf Module CUSTOM POWER CABLE TO CAB-MLP-0X CABLE PWR-120 Wire Color Meaning 24 V+ White 24 V+...
CAB-MS0x The Matrix 450N uses the CAB-LD-102 no power cable between the reader and its relative LT-03x illu- minator. Figure 6 - Connecting PWR-120 to a Matrix 450N CUSTOM POWER CABLE TO CAB-LP-0X CABLE TO LT-03X PWR-120 Wire Color Meaning...
Primary wiring: Overcurrent protection should be provided by a 16 A building installa- tion circuit breaker. PWR-120 input components are rated for an Icp of 10 kA max. Wiring methods from the branch circuit breaker to the PWR-120 power supply shall comply with the National Electric Code ANSI\NFPA.
Page 20
AC LINE VOLTAGE ELECTRICAL CONNECTIONS Replace the protection cover over the spring clamp connector after correctly installing the wires. AC Line terminal block Protection covers Figure 1 - PWR-120 AC Line Terminal Block with Protection Covers PWR-120...
CHAPTER 6 TECHNICAL FEATURES ELECTRICAL FEATURES AC from 100 to 240 V Input Voltage from 50 to 60 Hz Input Current Consumption Max 6 A Icp 10kA - output at full load Output Voltage 24 Vdc Nominal Output Current Max Continuous Overcurrent 5.5 A (up to 40°...
APPENDIX A ELECTRICAL DIAGRAMS PWR-120 ELECTRICAL DIAGRAM The PWR-120 components are electrically connected as displayed in the following dia- gram: Figure 1 - PWR-120 Electrical Diagram PWR-120...