OPERATION
STATE SETTING OF DISPENSER
• Touch the key of the corresponding mode to select Ice Cube Mode/Water
Drainage Mode/Ice breaking mode.
• After the corresponding function is selected, the indicator light of the
corresponding mode will be on. Water will be drained out immediately after
water drainage mode is selected. Ice is drained out 3 seconds after the switch of
ice cube mode/ice breaking mode is pressed.
CONTROL OF DISPENSER LAMP
• When the dispenser switch is switched on, the dispenser lamp will turn on.
• When the dispenser switch is disconnected, the dispenser lamp will turn off after
a 3 second delay.
• Press the REF-ICE key to turn on the backlight and the ice maker. Press the REF-
ICE key again to turn off the backlight and the ice maker. It will take effect after
locking.
TIPS FOR REPLACING FILTER
When the filter is used for more than 150 days and the backlight is always on or
when the filter is used for more than 180 days and the backlight flashes, press
WATER-FILTER key for 3 seconds to clear the alarm settings and re-time it. The
buzzer rings 3 times.
MODE SETTINGS
QUICK COOLING MODE
• Press and hold the Refrigeration key for 3 seconds to enter the quick cooling
mode. At the same time, the icon of the refrigerating chamber will turn blue. The
quick cooling mode will take effect after being locked.
• At the time of setting the quick cooling mode, the temperature of refrigerating
chamber is automatically set at 33.8°. When the quick cooling mode is exited,
the set temperature of the refrigerating chamber automatically returns to the set
temperature before the quick cooling mode.
21
OPERATION
QUICK-FREEZING MODE
• Press and hold the Freezing key to enter the quick cooling mode. At the same
time, the icon of the freezing chamber will turn blue. The quick cooling mode will
take effect after being locked.
• At the time of setting the quick cooling mode, the temperature of refrigerating
chamber is automatically set at -7.6°F. When the quick cooling mode is exited,
the set temperature of the refrigerating chamber automatically returns to the set
temperature before the quick cooling mode.
ECO MODE
• Press ENERGY SAVING key to enter the ECO mode. The backlight will turn
on. The quick-freezing mode is canceled at the same time. The quick freezing is
controlled at 6.8° F and refrigerating at 44.6° F.
• Press the ENERGY SAVING key again to exit the ECO mode. The backlight
will turn off and the temperature of freezing and refrigerating will return to the
set temperature before entering the ECO mode. The mode will take effect after
locking.
ANTI-CONDENSATION HEATER STRIP
• The anti-condensation heater strip can be turned on and off by pressing
"ENERGY SAVING" and "FREEZER-TEMP" at the same time for 3 seconds. The
Fahrenheit symbol will blink, it will take effect by pressing the locking key, and
the anti-condensation heater strip will be turned off.
• When the anti-condensation heater strip is off, press "ENERGY SAVING" and
"FREEZER-TEMP" for 3 seconds. The Fahrenheit symbol will no longer blink. It
will take effect by pressing the locking key and the anti-condensation heater strip
will be turned on.
• The on and off anti-condensation heater strip are for inspection and maintenance
convenience. Please do not toggle this frequently, as it will cause the risk of
condensation.