5-2-2-2. Auto focus adjustment
• Basic iris adjustment
Measuring instrument None
Subject
Tape
Test point
None
Adjustment address
1FF
Adjustment level
09, 0A, 0B
1) Set up the auto focus adjustment mode. (Write 01 to the address 1FE)
2) Write the adjustment data 09, 0A and 0B one after the other to the address 1FF, the adjustment are as follows.
Data
Adjustment
09
Hall offset
0A
Iris offset
0B
Iris close
• Lens adjustment
Measuring instrument
None
Subject
More than 50 m away
Tape
Test point
None
Adjustment address
1FF
Adjustment level
11, 12, 06, 08
1) Set up the auto focus adjustment mode.
(This is unnecessary after the above basic iris adjustment has been made.)
2) Write the adjustment data 11, 12, 06 and 08 one after the other to the address 1FF. The adjustments are as follows.
3) Write FF to the address 1FE to exit the auto focus adjustment mode.
Adjustment
Data
11
Voltage adjustment
12
Optical wide-end adjustment
Wide-end focus ∞ position adjustment
06
Tele-end focus ∞ position adjustment
08
5-2-2-3.
Before starting these adjustments, set up the auto focus adjustment mode.
• Sync level adjustment
Measuring instrument Oscilloscope
Subject
Anything
Tape
Test point
VIDEO OUT (Terminated in 75Ω)
Adjustment address
1F8
Adjustment level
300mVp-p
1) Set up the camera signal line adjustment mode. (Write
00 to the address 1FE)
2) Connect the oscilloscope to the VIDEO-OUT. Adjust the
sync level to300mVp-p.
1H
5-15
VL-E610S/VL-E610H
VL-E660S/VL-E96E
VL-E98E
Video
SYNC
300mVp-p