Insulation resistance tester

Advertisement

Quick Links

HZJY-5K-I
Insulation Resistance Tester
Huazheng Electric Manufacturing (Baoding) Co., Ltd

Advertisement

loading
Need help?

Need help?

Do you have a question about the HZJY-5K-I and is the answer not in the manual?

Questions and answers

Summary of Contents for Huazheng HZJY-5K-I

  • Page 1 HZJY-5K-I Insulation Resistance Tester Huazheng Electric Manufacturing (Baoding) Co., Ltd...
  • Page 2 (0312) 6775656 to tell you to serve you at all times- Baoding Huazheng Elect ric Manufact ur ing Co. , Lt d. , our company will def initely make you satisf ied !
  • Page 3: Table Of Contents

    Contents I. Safe Use Items..........................1 II. Feature............................2 III. Specification Parameter......................3 IV. Introduction Of Instrument......................4 V. Instrument Using..........................7 VI. Packing List..........................8...
  • Page 4: Safe Use Items

    Safe Use Items Design and manufacture of the instrument and testing achieves IEC61010 safety standards (electronic measuring product safety requirements), this manual including the safety of the instrument use and ensure the safety of equipment state, users must follow the warnings and safety regulations Please read the following instructions before use. Warning ●...
  • Page 5: Feature

    ● Please do not install in the device replacement parts or any unauthorized modification, maintenance, please contact with me. ● Make sure all wires and instrument testing port connection is firm. Note (for improper operation may cause personal injury or equipment damage) ...
  • Page 6: Specification Parameter

    ● Perfect protection function, and the spare fuse prompt functions. III. Specification Parameter Safety Standard ● IEC 61010-1 CAT.IV 600V IEC 61326 EMC specification: test, control and electrical equipment for testing IEC60529 IP64 (Outer closed state) ● AC Power:220V±10%, 50 HZ ,20 VA ●...
  • Page 7: Introduction Of Instrument

    Unspecified > 100G > 200G > 1T > 1T IV. Introduction Of Instrument The Front Panel Description ● number Description number Description AC plug AC ON Test Port(E、G、L) LCD display ● Key and function Key numbered from left to right, the first for a total of five off down the power Key. number Description Press the switch on button startup, shutdown condition...
  • Page 8 ● Test setup interface Set test voltage SetThe test time Battery Indicator Set Short Current Set the filter Button function tip Soft key Description Power Off (No operation, 3 minutes automatic shutdown) Set test voltage: 500V、1000V、2500V、5000V TIME SetThe test time: 01:00>10:00>30:00 Switching software keys to a new function, or from other function to return Set Short Current,1 mA step selection Usually according to the...
  • Page 9 Follow these steps to set up: 1. In shutdown state, hold key 2 (the 2 key). 2. Press the 1 key (the power button), until into the contrast adjustment menu. 3. Press 1 or 2 keys to adjust contrast, until the right . 4.
  • Page 10: Instrument Using

    V. Instrument Using measured DAR:  1. Select more than 1 minute length measurement. 2. Select the appropriate voltage and start. 3. The instrument automatically record 15 s and 60 s resistance, and calculate the absorption than after 60 seconds. Absorption ratio calculation method: DAR = R60 / R15;...
  • Page 11: Packing List

    VI. Packing List Item Main engine Power line Red test line Black test line Green test line...