Using the figure below as a guide place the PCB cover back onto the flue damper control box as follows:
1.
Slide the PCB cover back over the Flue Damper PCB.
2.
Place the Top and Bottom Screws back into place and tighten to secure the PCB cover back in place.
PCB Cover
Using the figures below as a guide connect the wiring from the flue damper to the Imax Xtra 2 as follows:
1.
Remove connector I3_CN from Installation Connection I3.
2.
Connect the Live wire to Pin 3 of connector I3_CN.
3.
Connect the Neutral wire to Pin 2 of connector I3_CN.
4.
Connect the Earth wire to Pin 1 of connector I3_CN.
5.
Push connector I3_CN back into Installation Connection I3.
6.
Remove connector I12_CN_B from Installation Connection I12.
7.
Connect the Flue Damper Signal wire to Pin 1 of connector I12_CN_B.
8.
Connect the Flue Damper Feedback wire to Pin 2 of connector I12_CN_B.
9.
Push connector I12_CN_B back into Installation Connection I12.
Main Control Board
4
INSTRUCTIONS
Top Screw
Bottom Screw
I3
I12
B
Primary
PCB
IMAX XTRA 2 -
Flue Damper Kit Instructions