Garmin G1000 Maintenance Manual page 80

Hide thumbs Also See for G1000:
Table of Contents

Advertisement

____________________________________________________________________
SELECT UNIT—GIA2
RS-485 WINDOW
Channel
LRU
CHNL 1
GEA1
Page 5-34
Rev. A
Indicator
GIA2/GEA1 data path is functioning correctly.
GIA2/GEA1 data path is not functioning correctly.
Check PFD1 Alert Window for GIA or GEA
configuration or software error messages. Correct
any errors before proceeding.
Verify GEA1 status is OK using the AUX - SYSTEM
STATUS PAGE on the MFD. If it has a Red-X,
troubleshoot why the GEA is offline before
proceeding.
Swap GIA1 and GIA2, reconfigure both GIA's to
their new locations to confirm if the problem is in the
original GIA2.
Replace original GIA2 if box turns green after
swapping units.
Swap GEA1 and GEA2, reconfigure both GEA's to
their new locations to confirm if the problem is in the
original GEA1.
Replace original GEA1 if box turns green after
swapping units.
Check the GIA2/GEA1 interconnect wiring and
connector pins for faults.
GIA2/GEA1 data path functionality is unknown. Reload
GIA2 configuration files.
Status/Recommended Actions
G1000 System Maintenance Manual
190-00903-00