Advisory Message
PFD2 SERVICE – needs
service. Return unit for repair.
G1000 System Maintenance Manual
190-00903-00
Possible Cause
The G1000 has determined
PFD #2 needs service.
Recommended Actions
•
Ensure the PFD connector is
fully seated and locked.
•
If the unit was started in a very
dark environment the photocells
may not have enough light to
initially raise the CCFT level.
Go to the GDU STATUS page
in configuration mode, ensure
CCFT CRNT 1 & 2 levels are
above 50.
•
If the CCFT levels are not
above 50, apply light to the
photocell and observe if the
CCFT level rises.
−
If the CCFT level rises,
disregard the message.
−
If the CCFT level does not
rise, replace the PFD
•
Replace the PFD.
Page 5-61
Rev. A