Condenser Module Assembly Procedures - Safran PILATUS PC12 M19 Manual

Table of Contents

Advertisement

 
9.1.6. Tools, fixtures, equipment, or consumable items required
Small hand tools and socket set
Gates Sonic Tension Meter 508C or equivalent
Shop air, 40 PSIG max
Scribe or wire hook
Inspection mirror
Thermometer, 0-150°F
Flash light or service lamp
Leak check fluid (soapy), (MS-SNOOP-GAL)
Thread sealant primer
Thread sealant
Dry nitrogen, regulated (0-300 PSIG)

9.2. Condenser Module Assembly Procedures

9.2.1. Assembly of Outlet Shroud
9.2.1.1.
with section 6, apply a 1/8 inch bead of RTV to outlet shroud/coil mating surface.
9.2.1.2.
9.2.2. Assembly of Receiver Dryer
9.2.2.1.
9.2.2.2.
a thin layer of thread sealant primer to fitting threads.
CAUTION: APPLY THREAD SEALANT SPARINGLY TO THREADS STAYING CLEAR OF FIRST 2-3
THREADS.
9.2.2.3.
CAUTION: TAKE EXTREME CARE NOT TO GET REFRIGERANT OIL ON FITTING THREADS
Copyright © 2020 
Page | 35 
After insuring that the shroud/coil mating surfaces have been cleaned in accordance
Attach fan / outlet shroud to coil with mounting bolts, washers and nuts (refer to table
1, Section 1 for torque specifications).
Carefully slide receiver dryer into mounting clamps and tighten.
Using a wire brush and cleaning solvent, completely remove old thread sealant. Apply
Apply 1-2 drops of thread sealant on receiver dryer inlet port threads.
Original Release 
12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
www.enviro-ok.com
passenger
www.safran‐
ATA 21‐00‐60 
‐solutions.com

Advertisement

Table of Contents
loading