9.1.6. Tools, fixtures, equipment, or consumable items required
•
Small hand tools and socket set
•
Gates Sonic Tension Meter 508C or equivalent
•
Shop air, 40 PSIG max
•
Scribe or wire hook
•
Inspection mirror
•
Thermometer, 0-150°F
•
Flash light or service lamp
•
Leak check fluid (soapy), (MS-SNOOP-GAL)
•
Thread sealant primer
•
Thread sealant
•
Dry nitrogen, regulated (0-300 PSIG)
9.2. Condenser Module Assembly Procedures
9.2.1. Assembly of Outlet Shroud
9.2.1.1.
with section 6, apply a 1/8 inch bead of RTV to outlet shroud/coil mating surface.
9.2.1.2.
9.2.2. Assembly of Receiver Dryer
9.2.2.1.
9.2.2.2.
a thin layer of thread sealant primer to fitting threads.
CAUTION: APPLY THREAD SEALANT SPARINGLY TO THREADS STAYING CLEAR OF FIRST 2-3
THREADS.
9.2.2.3.
CAUTION: TAKE EXTREME CARE NOT TO GET REFRIGERANT OIL ON FITTING THREADS
Copyright © 2020
Page | 35
After insuring that the shroud/coil mating surfaces have been cleaned in accordance
Attach fan / outlet shroud to coil with mounting bolts, washers and nuts (refer to table
1, Section 1 for torque specifications).
Carefully slide receiver dryer into mounting clamps and tighten.
Using a wire brush and cleaning solvent, completely remove old thread sealant. Apply
Apply 1-2 drops of thread sealant on receiver dryer inlet port threads.
Original Release
12037 N Highway 99
Seminole, OK 74868
Phone (405) 382-0731
www.enviro-ok.com
passenger
www.safran‐
ATA 21‐00‐60
‐solutions.com