If blower motor wheel is damaged, such as having bent or cracked blades,
removal and replacement is required.
If blower motor scroll is damaged in any way, the entire Evaporator Module
Assembly must be removed and sent to Enviro Systems for repair.
If the blower motor is damaged or is not operating to specifications, motor will
need to be removed and replaced.
Condensate Drain
The condensate drain (part of the housing assembly) can, over time, become
damaged. It is essential that the drain remains in excellent condition for proper
operation of the evaporator coil assembly. If the condensate drain is damaged, the
entire assembly must be removed and sent to Enviro Systems for repair.
Expansion Valve
The expansion valve can, over time, become damaged and/or not operate correctly. If
the expansion valve shows signs of damage or does not function properly, remove
and replace.