The list below shows the history of the fi rmware versions in the IntelliTec2 control. The information in this manual
refers to Version 20.27.
VERSION 20.27 - CURRENT VERSION
Released on 12/28/10
• Added Unit Serial Number to Service Contact Information and Modify Contact Information
• Added Clean Warning to Clean Options
VERSION 20.15
Released 11/23/10
• Added Enable Control to Basic Settings
• Removed Enable CutOut Temp from Basic Settings
• Changed CutOut Consistency to CutOut Consistency Offset
• Added CutIn Consistency Offset
• Moved Sleep 1 Drive On and Sleep 1 Drive Off to Factory Settings from Advanced Settings
• Moved Stir On and Stir Off to Advanced Settings from Factory Settings
• Added Storage Refrigeration to Storage Settings
• Storage CutIn changed to 37.5°F (was 37°F)
• Moved Pressure Sensing and Liquid Sensing to Factory Settings
• Added Clean Options to Utilities page 1
• Moved Clean Lockout to Clean Options from Utilities page 1
• Added Clean History Log to Clean Options
VERSION 17.19
Released on 9/8/10
Note: They are few initial machines with 15.19 (8/23/10) where cutout consistency was 70, then pulleys were
changed. Two machines with 16.19 had 60 as cutout limit, then some minor internal reset timers were changed
and 17.19 released on 9/8/10
• Consistency Limit changed to 60 (was 110 for 1 phase / 80 for 3 phase)
• Moved Stir On and Stir Off to Factory Settings from Basic Settings
• Enable CutOut Temp and CutOut Temp moved to Basic Settings from Factory Settings
• Sleep 1 Drive Off changed to 600 seconds (was 300 seconds)
• Sleep 2 CutIn changed to 33°F (was 38°F)
• Sleep 2 CutOut changed to 30.5°F (was 30°F)
(continued on next page)
INTELLITEC2 FIRMWARE
VERSION UPDATE LOG
iii