Stoelting F231 Service Manual page 12

Hide thumbs Also See for F231:
Table of Contents

Advertisement

https://appliancetechmanuals.com
Serve Mode / Serve 2 Mode
Freezing Cycle
Cycles Until Sleep*
* Resets any time the PUSH TO FREEZE button is pressed or a spigot is pulled. In order for the mode to change, it has to go through its normal
cycles without reset.
Note:
1) A stir cycle will start in each mode. The cycle is independent of the freezing cycle.
2) Normal start up mode is Sleep 1 when the number of cycles is set below 99. When cycles are set higher than 99,
the freezer will start up in the Serve mode.
3) Sensor failure will keep the control in Serve and Standby modes only.
4) A freeze cycle will reset the stir cycle.
5) Serve Mode is active for the Temperature/Consistency setting and monitors CutIn Temperature. Serve 2 Mode is
active for the Consistency/Consistency setting and monitors CutIn Consistency. Both use CutOut Consistency.
IntelliTec2 Control Modes of Operation
PUSH TO FREEZE or Spigot Pull
Standby Mode
Standby
On Time
CutIn
Temperature
or
Consistency
CutOut
Consistency
Standby Time*
PUSH TO FREEZE or Spigot Pull
Sleep 1 Mode
Standby
Off Time
Standby
Time
Sleep 2 CutIn*
PUSH TO FREEZE or Spigot Pull
Sleep 2 Mode
Sleep 2 CutIn
Sleep 2 CutIn
Sleep 2 Cutout