This system has been tested according to NSF/ANSI Standard 42 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to
the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine
Taste and Odor and Nominal Particulate Class I.
Capacity of 300 gallons (1,135 liters).
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Contaminant
Average
Reduction
Particulate
Class I Particle size:
5600000
> 0.5 to < 1 um
Chlorine taste and odor
Application Guidelines/Water Supply Parameters
Water pressure
30 - 100 psi (207 - 689 kPa)
Water temperature
33 - 100°F (0.6 - 37.8°C)
Service flow
0.5 gpm (1.9 lpm)
w w WARNING
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
Entire system (excluding disposable cartridge) is warranted
for a period of one year from date of purchase. Disposable
cartridges are warranted for defects in material and
workmanship only. Service life of disposable filter cartridges
varies with local water conditions and is thus not warranted.
Flush the refrigerator water system after replacing the water
filter cartridge. Flush 2.5 gallons through filter before use
(flush for approximately 5 minutes).
After replacing the cartridge, reset the water filter status
display and indicator light by pressing and holding the reset
button for 3 seconds.
Systems must be installed and operated in accordance with
manufacturer's recommended procedures and guidelines.
w w CAUTION: Change the filter cartridge at least every
six months.
IMPORTANT: Failure to follow installation, operation
and maintenance instructions will void warranty. See
warranty card for complete details.
All manuals and user guides at all-guides.com
Performance Data Sheet For Model 5231JA2006A-S
Using Replacement Cartridge 5231JA2006A
Influent Challenge
concentration. Units apply
Influent
to each row
At least 10,000
particles/ml
1.9
2.0mg/L±10%
FILTER
Average
Product
NSF Reduction
%
Water
Requirements
Reduction
383333
93.2
0.05
97.4
To reduce risk of property damage due to water leakage:
• Read and follow Use Instructions before installation and
use of this system.
• Install on COLD water lines only.
• Comply with all state and local plumbing codes.
• Never install or operate where inlet water pressure may
exceed 120 psi (827 kPa).
• Protect fiIter from freezing. Remove filter in temperatures
below 33°F (0.6°C).
• Replace cartridge at specified service interval.
Cartridge MUST be replaced at least every 6 months.
To purchase a replacement filter, visit your local Sears store
or call 1-800-4-MY-HOME
Visit us on the web at www.sears. com
25
Max.
Min.%
Effluent
Reduction
mg/L
≥ 85%
470000
91.6
≥ 50%
0.05
97.4
w w CAUTION
.
®
NSF Test
511032-03
511031-03