Menu Overview - Bosch Rego 1000 User Manual

Table of Contents

Advertisement

5

Menu overview

The top menu for the customer is:
• 1 Room temperature
• 2 Hot water
• 3 Holiday
• 6 Energy measurements
• 7 Timers
No.
1
Room temperature
1.1
1.1.5
1.1.6
Compressor 1 operating time on/off
1.1.7
Compressor 2 operating time on/off
1.1.10
1.1.10.1
Room temperature influence (with room sensor)
1.1.11
Room temperature program
1.1.11.1
1.1.11.2
View/edit active program
1.1.11.3
Room temperature normal
1.1.11.4
Temperature increase/decrease (no room sensor)
1.1.11.6
Room temperature influence
1.1.11.7
Room temperature exception
1.1.11.8
Copy to all heating circuits
1.3
1.3.5
Heat curve (see 1.1.5)
1.3.7
Room sensor (see 1.1.10)
1.3.8
Room temperature program (see 1.1.11)
1.4
Circuit 3 (option) (see 1.3)
1.5
Circuit 4 (option) (see 1.3)
1.10
1.10.1
Summer/winter operation
1.10.1.1
1.10.1.2
Outdoor temperature limit for change over
2
2.2
2.3
2.3.1
Extra hot water duration
2.3.2
Extra hot water stop temperature
2.4
2.4.1
2.4.2
2.4.3
2.5
2.5.1
2.5.2
View/edit active program
3
3.1
Circuit 1 and hot water
3.1.1
Activate holiday function
3.1.2
3.1.3
3.1.4
Room temperature
3.1.5
Copy to all heating circuits
3.1.6
Block hot water production
3.2
Circuit 2 (option) (see 3.1)
3.3
Circuit 3 (option) (see 3.1)
3.4
Circuit 4 (option) (see 3.1)
6
Energy measurements
Table 3 Menu overview
Rego 1000 – 6 721 831 662 (2021/03) en
Name
Circuit 1 Heating
Heat curve
Room sensor
Active program
Circuit 2 (option)
General
Winter operation
Hot water
Hot water mode
Extra hot water
Hot water peak
Day of the week
Interval in weeks
Start time
Hot water program
Active program
Holiday
Start date
Stop date
• 8 External control
• 12 General
• 13 Alarms
• 14 Access level
• 15 Return to factory settings
Factory value = F-value
HP x = Heat pump 1 or 2 / Compressor 1 or 2
F value
Min.
20,0
10,0 ( Comfort )
20,0
10,0 ( Comfort )
3,0
0,0
HP optimized
20,0 °C
10,0 °C
=
3,0
0,0
17 °C
10 °C
No
Automatic
18 °C
5 °C
Economy
0h
0h
65,0 °C
50,0 °C
None
1
1
3:00
0:00
Always hot water
No
17,0 °C
10,0 °C
No
No
Menu overview
Max.
Alternative
30,0 ( Economy )
30,0 ( Economy )
10,0
HP optimized /
Program 1 / Program 2
35,0 °C
--/-/+/++
10,0
30 °C
No / Yes
On / Automatic / Off
35 °C
Comfort / Economy
48h
65,0 °C
None /Day/ All
4
23:00
Always hot water /
Program 1 / Program 2
No / Yes
35,0 °C
No / Yes
No / Yes
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents