Siemens SMART 7KT Manual page 19

Multifunction meter
Hide thumbs Also See for SMART 7KT:
Table of Contents

Advertisement

Modbus register addresses list (Continued)
Readable / writable parameters: [Data Structure: Integer]
Hex
Address
Address
40000
0x00
Password
40001
0x01
N/W Selection
40002
0x02
CT Secondary
40003
0x03
CT primary (CT Secondary=5)(A)
CT primary (CT Secondary=1)(A)
40004
0x04
PT Secondary
40006
0x06
PT primary
40007
0x07
Slave id
40008
0x08
Baud rate
40009
0x09
Parity
40010
0x0A
Stop bit
40011
0x0B
Backlight OFF
40012
0x0C
Factory Default
40016
0x10
Auto Mode Pages
40017
0x11
Page Address Sequence
40018
0x12
Page Address Sequence
40019
0x13
Page Address Sequence
40020
0x14
Page Address Sequence
40021
0x15
Page Address Sequence
40022
0x16
Page Address Sequence
40023
0x17
Page Address Sequence
40024
0x18
Page Address Sequence
40025
0x19
Page Address Sequence
40026
0x1A
Page Address Sequence
40027
0x1B
Page Address Sequence
40028
0x1C
Page Address Sequence
40029
0x1D
Page Address Sequence
40030
0x1E
Page Address Sequence
40031
0x1F
Page Address Sequence
40032
0x20
Page Address Sequence
40033
0x21
Page Address Sequence
40054
0x36
Page Address Sequence
40055
0x37
Page Address Sequence
40059
0x3B
Page Address Sequence
40060
0x3C
Page Address Sequence
40061
0x3D
Page Address Sequence
40034
0x22
Demand Interval Method
40035
0x23
Demand Interval Duration
40036
0x24
Demand Interval Length
40043
0x2B
Reset Max
40044
0x2C
Reset Energy
40046
0x2E
Reset ON Hour
Parameter
Min value: 0
Value: 0
Value: 1
Value: 2
Value: 3
Value: 4
Min value: 1
Min value: 5
Min value: 1
Min value: 100 Max value: 500
Min value: 100 Max value: 500kV
Min value: 1
Value: 0x0000 Meaning: 300
Value: 0x0001 Meaning: 600
Value: 0x0002 Meaning: 1200
Value: 0x0003 Meaning: 2400
Value: 0x0004 Meaning: 4800
Value: 0x0005 Meaning: 9600
Value: 0x0006 Meaning: 19200
Value: 0x0000 Meaning: None
Value: 0x0001 Meaning: Odd
Value: 0x0002 Meaning: Even
Value: 0x0000 Meaning: 1
Value: 0x0001 Meaning: 2
Min Value: 0
Value: 1
Min Value: 1
Page No
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
1-22
Value: 0x0000 Meaning: Sliding
Value: 0x0001 Meaning: Fixed
MIN Value: 1
MIN Value: 1
Value: 1
Value: 1
Value: 1
Range
Max value: 9998
Meaning: 3P4W
Meaning: 3P3W
Meaning: 1P2W-P1
Meaning: 1P2W-P2
Meaning: 1P2W-P3
Max value: 5
Max value: 10000
Max value: 10000
Max value: 255
Max Value: 7200
Meaning: Set to factory setting range
Max Value: 22
Meaning
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
1-First Page; 22-Last Page
MAX Value: 30
MAX Value: 30
Meaning: Reset all Max power
Meaning: Reset all energyto factory setting range
Meaning: Reset ON hour
SMART 7KT0310 Manual
Length
(Register)
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7kt0310

Table of Contents