When entering in ADJUST MODE, LCD indication becomes as follows.
READY
A4
or
LET
In this condition, it is entered in menu by depressing [MENU] key. Setting items are as follows.
. LETTER/A4 (Selection of letter or A4 paper)
Selection paper size by depressing [←] or [→] key.
. Std (Gamma correction selection for standard media)
CG ....... For CG market
P1 ......... For photograph market
. Lami (Gamma correction selection for lamination media)
L1 ........ There is a masking.
L0 ........ There is no masking.
Above three items are set according to the destination of model.
UC model ........ LETTER, P1, L0
J, CE model ..... A4, CG, L0
. VOLT (Fine adjustment of head voltage)
LCD indication is as follows.
VOLT = 17.7 [+0.0]
R = 4257 (ohm)
Number at left side of voltage value is the head voltage value that is calculated from average resistance
value of the head built in the unit. (Head temperature 35 dC, starting point when printing the ordinary
paper.) If the most density is not obtained at this voltage, fine adjustment should be performed by
depressing [←] or [→] key. Fine adjustment voltage is indicated at inside of [ ] of right side.
. THERMAL FILM (Fine adjustment of head voltage when printing the film)
Density of the thermal film can be finely adjusted as in the case of VOLT.
n
When using the ROM in version 1.00, update it to 1.10 or later version.
LCD indication is as follows.
[_0.1]
THERMAL FILM
. BCD D/A (Bar code sensor luminance quantity adjustment)
. RIBBON D/A (Ribbon code sensor luminance quantity adjustment)
. OHP D/A (OHP sensor luminance quantity adjustment)
Bar code, ribbon code and OHP sensors are adjusted to the most LED luminance quantity using D/A
converter. When replacing each sensor or EEPROM, the adjustments should be performed.