s) Ribbon code sensor/luminance quantity adjustment (CN5-3, 19)
Function
: This is a transmission type sensor that reads ribbon code and starting mark on the
ink ribbon. Pair LED luminance is set to obtain the most suitable luminance
quantity. When reading ribbon code every time, the threshold level value for
judging L or H is changed to the most suitable value.
Level
: Ribbon code portion is H, others are L
Check method : Make sure the threshold level, ribbon cassette should be inserted, ribbon should be
rotated correctly, make sure the sensor output.
t)
OHP sensor/luminance quantity adjustment (CN5-15, 21)
Function
: This is a transmission type sensor that detects paper kind after feeding paper. Pair
LED luminance is set to obtain the most suitable luminance quantity. When reading
ribbon code every time, the threshold level value for judging L or H is changed to
the most suitable value.
Level
: Ordinary paper is H, OHP is L.
Check method : Make sure the threshold level, transmit the paper, and make sure sensor the output.
u) Head thermistor (CN7-27)
Function
: This thermistor measures temperature of the thermal head.
: Approximately 2.5 V at the normal temperature (25 dC)
Level
Check method : Measure the voltage of thermistor.
v) Room thermistor (CN4-17)
Function
: This thermistor measures the temperature at the inside of the unit.
: Approximately 2.5 V at the normal temperature (25 dC)
Level
Check method : Measure the voltage of thermistor.