Troubleshooting - Rehau RAUTOOL A-LIGHT2 Product Instructions

Table of Contents

Advertisement

RAUTOOL A-LIGHT2

TROUBLESHOOTING

Defect
Cause
Motor does not run
- Tool/battery contacts dirty
- Tool/battery contacts damaged
- Battery not correctly locked into the tool
- Battery empty
- Battery faulty
- Tool faulty
Tool leaking oil
- Leak in oil tank or release valve
Tool does not reach
- Leak in oil tank or release valve
final pressure
- Air in the hydraulic system
- Tool faulty
Battery does not
- Charger not plugged in correctly
charge
- No power coming to socket
- Charger/mains cable or plug damaged
- Charger not ready
- Charger/battery contacts dirty
- Charger/battery contacts damaged
- Battery not locked correctly into the charger
If the defects cannot be remedied, send the tool to your local REHAU representative .
Correction
Clean contacts when dry with non-conducting material
Send tool/battery to your local REHAU representative
Reinsert battery, pay attention to locking mechanism
Charge battery
Give battery to the recycling system
Send tool to your local REHAU representative
Do not open the tool and do not remove or damage
the tool seal; send tool to your local REHAU representative
Do not open the tool and do not remove or damage
the tool seal; send tool to your local REHAU representative
Interrupt the compression process
Hold reset knob under tension (see page 6/no. 2) and at
the same time continuously activate the operating switch
for about 10 sec. If this does not correct the defect, the tool
must be sent to your local REHAU representative.
Return tool to your local REHAU representative
Reinsert mains plug
Change socket
Send charger your local REHAU representative
Wait for green LED to flash
Clean contacts when dry with non-conducting material
Send charger/battery to your local REHAU representative
Reinsert battery, paying close attention to locking mechanism
15

Advertisement

Table of Contents
loading

Table of Contents