Problems Programming the Panel

Before attempting to program the panel, you should be familiar with the basic operation of
the D5200 programmer. See the D5200 Operation Manual (74-06176-000). If you still
experience problems, check for the symptoms below.
33317D 4/97
Symptom
The programmer
The programmer is
displays PLUG IN
not correctly
D9412/D9112
connected to the
when you press
D9412/D9112.
SEND or RECV.
AC induction through
the on-board point
sensor loops, the
DATA BUS, or the
ZONEX BUS.
After plugging in
You haven't entered
the D9412/D9112
the programmer,
the panel
handler within 30
transmits SDI
seconds of plugging in
trouble reports for
the programmer.
supervised SDI
devices
(command
centers, printer
interface modules,
etc.). All SDI
devices stop
operating.
D9000/D7000 Series Installation and Troubleshooting Quick Reference
Diagnosis
1. Verify that the data/power cord is plugged
2. Verify that the data/power cord is plugged
3. Check each conductor in the data/power
1. Verify a proper earth ground at terminal
2
Enter the D9412/D9112 handler within 30
seconds of plugging in the programmer.
Once the SDI reports are generated, sending
or receiving a handler or disconnecting the
programmer returns the SDI devices to
normal operation.
Page 7
Remedy
into the COMMUNICATOR port on the
D5200.
securely into the D9412/D9112
programmer connector (J7).
cord for continuity.
10.
Disconnect on-board point sensor loops,
the DATA BUS (terminals 30, 31), and the
ZONEX BUS (terminals 25, 26,27,28).