Installing The Device Outdoors - Siemens SIMATIC NET Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Installing the Device
2.4 Installing the Device Outdoors
Removing the Device
To remove the device from a DIN rail, do the following:
1.
2.
3.
2.4

Installing the Device Outdoors

When installing the RP100 outdoors, make sure there is a solid connection between
the lightning protector and the CPE/PD. The following illustration details a typical
installation:
Note
A shielded cable must be used and connected to local ground at both the RP100 and
CPE/PD.
Note
The lightning protector must meet the necessary requirements of IEC/UL/CSA
62368-1. The clamping voltage must also be less than 60 V and the protector must
not activate when the voltage is less than 56 V. For more information, contact
Siemens Customer Support.
8
Insert a flathead screwdriver into the slot of the sliding release and move it
down.
1
DIN Rail
1
DIN Rail Adapter
2
Figure 2.2
Removing the Device from a DIN Rail
Swing the bottom of the device away from the DIN rail.
Lift the device off the DIN rail.
2
Installation Manual, 01/2021, C79000-G8976-1011-05
3
1
2
1
RUGGEDCOM RP100

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ruggedcom rp100