Air-cooled gas engine generator sets

Advertisement

Home Standby - 16kW
TRANSFER SWITCH & EMERGENCY LOAD CENTER
No. of Poles ......................................................................................................................................... 2
Current Rating (amps) ....................................................................................................................... 100
Voltage Rating (VAC) ........................................................................................................................ 250
Utility Voltage Monitor (fixed)
-Pick-up
-Dropout
Return to Utility
.................................................................................................... approx. 13 sec.
Exerciser weekly for 12 minutes .................................................................................................... Standard
UL Listed ....................................................................................................................................... Standard
Dimensions (H" x W" x D") ....................................................................................................... 26.5 x 12.5 x 7
Total of Pre-wired Circuits .................................................................................................................. 16
No. 15A 120V ................................................................................................................ 5
No. 20A 120V ................................................................................................................ 5
No. 20A 240V ................................................................................................................ 1
No. 40A 240V ................................................................................................................ 1
No. 50A 240V ................................................................................................................ 1
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts .................................................................................................... 10,000
W2
W1
H1
C A R R I E R , I N C .
CarrierAC16kW 9.06
................................................................................................... 70%
................................................................................................... 60%
Mechanical Dimensions (in inches)
Current
No. of
Rating
Poles
100 UL Listed
Terminal Wire Ranges
ATS Rated Amps
H2
100A 2-Pole UL
7 3 1 0 W E S T M O R R I S S T R E E T
W E B S I T E : w w w . c a r r i e r . c o m
CATALOG NO. ASPBS16-1SS
Models: ASPBS1CC016 & ASPBA1CC016
Height
Width
H1
H2
W1
2
26.5
29.25
8.14
Switch Terminal
Neutral Lug/Stud
1 x 1/0-12
1 x 3/8-16 Stud
Conduit sizes
vary depending
on model #
© 2006 Carrier Corporation. All rights reserved. All specifications are subject to change without notice.
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for
fast, positive connections.
• Rated for all classes of load,
100% equipment rated, both
inductive and resistive.
• 2 pole, 250 VAC contactors.
• 160 millisecond transfer time.
• Dual coil design.
• Main contacts are silver plated
or silver alloy to resist welding
and sticking.
• Nema 1 enclosure is standard
on the 100 amp switch.
Depth
W2
12.5
7
Ground Lug
1 x 2/0-14
I N D I A N A P O L I S , I N 4 6 2 3 1