Samsung AM AXV Series Installation Manual page 55

Table of Contents

Advertisement

Optional item
Input unit
Silent mode
Main
High-head condition
Main
setting
Long-piping
Main
condition setting
Energy control
Main
operation
Rotation defrost
Main
(HR only)
Expand operational
temperature range
Main
for cooling operation
(HR only)
Channel address
Main
Snow accumulation
Main
prevention control
Unused option
Main
Unused option
Main
SEG1
SEG2
SEG3
SEG4
0
0
0
1
0
2
0
3
0
4
0
7
0
5
0
6
0
7
0
8
9
0
0
0
0
1
0
8
0
2
0
3
0
0
0
1
9
0
0
2
0
0
0
1
1
0
0
2
0
0
1
1
0
1
0
0
1
2
0
1
A
U
1
3
0 ~ 15
0
0
1
4
0
1
1
5
0
0
1
6
0
0
Function of the option
Disabled (Factory default)
LEVEL 1 / Auto
LEVEL 2 / Auto
LEVEL 3 / Auto
LEVEL 1 / External contact
LEVEL 2 / External contact
LEVEL 3 / External contact
LEVEL 1
LEVEL 2
LEVEL 3
Disabled (Factory default)
Level 1 of height difference type 1
(Indoor unit is lower than outdoor
unit)
Level 2 of height difference type 1
(Indoor unit is lower than outdoor
unit)
Height difference type 2 (Outdoor
unit is lower than indoor unit)
Disabled (Factory default)
LEVEL 1
LEVEL 2
Basic (Factory default)
Energy saving
Power
Disabled (Factory default)
Enabled
Disabled (Factory default)
Enabled
Automatic setting (Factory default)
Manual setting for channel 0~15
Enabled (Factory default)
Disabled
Unused option
Unused option
Remarks
Enables the silent mode for night-
time in cooling mode (It operates
automatically depending on the
temperature.)
However, if the external contact
interface module (MIM-B14) is used,
entering the silent mode is available
with contact signal in cooling and
heating mode.
When outdoor unit is located
40~80m above the indoor unit
When outdoor unit is located over
80m above the indoor unit
When indoor unit is over 30 m above
the outdoor unit
When equivalent length of farthest
indoor unit from the outdoor unit is
between 100~170m
When equivalent length of farthest
indoor unit from the outdoor unit is
over 170m
Energy control option of designated
operation sequence
Operating in energy saving mode,
capacity might decrease compared to
normal operation mode
When enabled, continuous heating
operation is possible but heating
performance will decrease during
rotation defrost operation
When enabled, continuous cooling
operation is possible even in low
temperature condition up to -15°C,
but noise of the MCU will increase
Address for classifying the product
from upper level controller (DMS,
S-NET 3, etc.)
During snow accumulation, the fan
may spin even when the unit is not
in operation
Unused option by this model
Unused option by this model
English
55

Hide quick links:

Advertisement

Table of Contents
loading