Troubleshooting - Hilti DX 6 Original Operating Instructions

Hide thumbs Also See for DX 6:
Table of Contents

Advertisement

Available languages

Available languages

6.5
Driving fasteners
1. Position the fastening tool.
2. Hold the fastening tool perpendicular to the working surface and then press it at right angles against the
surface.
3. Press the trigger to drive the fastener.
6.6
Unloading the single-fastener tool
1. Pull the cartridge strip up and out of the fastening tool.
2. Pull the fastener out of the fastening tool.
6.7
Unloading the magazine tool
1. Pull the cartridge strip up and out of the fastening tool.
2. Pull the magazine shutter down and remove the nail strip.
6.8
Resetting the cleaning indicator
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
The cleaning indicator is designed to indicate the correct cleaning intervals when the following
cartridges are used:
DX 6 cartridge titanium-gray
DX 6 cartridge, black
▶ Press the operating button at the display and hold it down for 10-12 seconds.
▶ The cleaning indicator is reset.
7

Troubleshooting

WARNING
Risk of explosion! Cartridges may fire (explode) if handled improperly.
▶ Do not use force to remove cartridges from the fastening tool or the magazine strip.
WARNING
Hazard due to hot surfaces! The fastening tool can become hot in use.
▶ Wear protective gloves.
7.1
Fastening tool jams and does not extend
DANGER
Risk of injury by unsecured fastening tool! If it jams in the compressed state, the fastening tool might be
loaded with the safety off. Unintentional triggering can cause severe injuries.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
1. Keep the fastening tool pressed against the work surface for at least 10 seconds and trigger the fastening
tool again.
2. Lift the fastening tool away from the working surface.
Be sure not to point it toward yourself or other persons!
3. Try to pull the fastener guide to its initial position by hand.
Take your hand off the trigger and do not hold your hand in front of the muzzle!
4. Immediately pull the cartridge strip out of the fastening tool.
If the cartridge strip cannot be removed:
▶ Allow the fastening tool to cool down at a safe location under observation.
▶ At all times, make sure that the fastening tool is not pointing toward you or anyone else.
▶ Contact Hilti Service.
5. Service the tool. → page 13
*2232123*
8
2232123
English