6.APPENDIX
(2) Cable specification
1.
Single phase unit
Nameplate
maximum
Phase line
current
No more
2
than 13A
2 1.5mm
2
13~25A
2 4mm
2
2 6mm
25~30A
2
2 10mm
30~40A
2
2 16mm
40~55A
2
2 25mm
55~70A
2. Three
phase unit
Nameplate
maximum
Phase line
Neutral line
current
No more
2
3 1.5mm
1.5mm
than 13A
2
3 4mm
4mm
13~25A
2
3 6mm
4mm
25~30A
2
3 10mm
30~40A
4mm
2
40~55A
3 16mm
4mm
2
3 25mm
55~70A
4mm
When the unit will be installed at outdoor, please use the cable which can against UV.
Creepage protector
Earth line
MCB
2
1.5mm
20A
30mA less than 0.1 sec
2
30mA less than 0.1 sec
4mm
40A
2
6mm
40A
30mA less than 0.1 sec
10 mm
2
63A
30mA less than 0.1 sec
2
16 mm
80A
30mA less than 0.1 sec
2
30mA less than 0.1 sec
25 mm
100A
Creepage protector
Earth line
MCB
2
2
30mA less than 0.1 sec
1.5mm
20A
2
2
4mm
40A
30mA less than 0.1 sec
2
2
6mm
30mA less than 0.1 sec
40A
2
2
10mm
63A
30mA less than 0.1 sec
2
2
80A
30mA less than 0.1 sec
16mm
2
2
25mm
100A
30mA less than 0.1 sec
29
Signal line
2
n 0.5mm
Signal line
2
n 0.5mm