  • Page 1 SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual...
  • Page 3 CONTENTS 1. Preface 2. Specifications 2.1 Performance Data of Swimming Pool Heat Pump Unit 2.2 Dimensions for Swimming Pool Heat Pump Unit 3. Installation and Connection Installation illustration Swimming Pool Heat Pumps Location 3.3 How Close to Your Pool? 3.4 Swimming Pool Heat Pumps Plumbing 3.5 Swimming Pool Heat Pumps Electrical Wiring 3.6 Initial Start-up of the Unit 4.
  • Page 4: Preface

    1. PREFACE In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance.
  • Page 5: Specifications

    2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R410A OASIS Ci 13 OASIS Ci 10 UNIT Nominal Heating Capacity 31960 Btu/h By 50Hz 24140 3.8~17.0 2.85~12.0 Range Btu/h 12920~57800 9690~40800 Nominal Heating Power 1.30 0.99...
  • Page 6 2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R410A OASIS Ci 17 UNIT OASIS Ci 21 OASIS Ci 25T 11.5 Nominal Heating Capacity 14.3 17.2 39100 By 50Hz Btu/h 48620 58480 4.6~19.5 5.7~24.2 6.7~28.3 Range Btu/h 15640~66300...
  • Page 7: Dimensions For Swimming Pool Heat Pump Unit

    2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit OASIS Ci 10 unit:mm Water outlet Φ40 Water inlet Φ40 Model OASIS Ci 13 OASIS Ci 17 unit:mm 1163 Water outlet Φ40 Water inlet Φ40...
  • Page 8 2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit OASIS Ci 21/OASIS Ci 25 unit:mm 1163 Water outlet Φ40 Water inlet Φ40...
  • Page 9: Installation And Connection

    3.INSTALLATION AND CONNECTION 3.1 Installation illustration Valve Chlorinator cell Water outlet Water supply Pool Water inlet Sand filter Water pump (or other type filter) Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer.
  • Page 10: Swimming Pool Heat Pumps Location

    3.INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh Air - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoors. For indoor pools please consult the supplier.
  • Page 11: Swimming Pool Heat Pumps Plumbing

    3.INSTALLATION AND CONNECTION 3.4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass(please set the flow rate according to the nameplate). The water pressure drop is less than 10kPa at max. Flow rate. Since there is no residual heat or flame Temperatures, The unit does not need copper heat sink piping.
  • Page 12: Swimming Pool Heat Pumps Electrical Wiring

    3.INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit.
  • Page 13: Operation And Use

    4.OPERATION AND USE 4.1 Color screen wire controller interface introduction (1) Main interface ⑦ ⑧ ① ② ③ ④ ⑤ ⑥ ⑨ (2) Button Description Name The button function ① ON/OFF Press to start /shut off the unit Click this button to view the unit state and the Parameter ②...
  • Page 14: Color Screen Wire Controller Function Introduction

    4.OPERATION AND USE 4.2 Color screen wire controller function introduction (1) Booting and shutdown As shown in figure 1.1: In shutdown status, click ① then the unit will be booted In booting status, click ① then the unit will be shut down. (2) Mode switch and target temperature Setting 2.2 1 Mode switch In the main interface, click mode button or inlet water temperature setting...
  • Page 15 4.OPERATION AND USE (3) Clock setting In the main interface, click on the clock Settings button, interface displays as follows: ① ② 3-1The operation of time setting Click on the time Settings button ① , interface displays as follows: Click the value to set time directly, the click confirm button to save the Settings.
  • Page 16 4.OPERATION AND USE 3-2 The operation of timing setting Click the timing set button ② to enter timing setinterface. ① ② ③ ④ Button function Name Button color Start: green Timing star b tu tton Click this button to start or end ①...
  • Page 17 4.OPERATION AND USE (4) Silent setting and silent timing setting as follows: Click the silent setting button ,and the interface displays ① ② 4-1 The silent button ① Click the silent button , the unit will enter the silent mode, and interface displays as follows: ①...
  • Page 18 4.OPERATION AND USE 4-2 Timing silent function setting Click timing silent button ② , and interface displays as follows: ① ② ③ ④ Name Colur Function Used: red Click to use or unuse timing Timing silent off ① Unused:gray off function Click to use or unuse timing Use:green Timing silent on...
  • Page 19 4.OPERATION AND USE (5) History of the fault In the main interface click fault display key, interface displays as follows: Fault time day - month - year The fault name Fault code hour:min If no failure, main interface displays static " "...
  • Page 20 4.OPERATION AND USE (6) Temperature curve In the main interface, click the curve display button, interface displays as follows: 2.6.1 Temperature recording curve is as follows: 6-2 The average power curve Temperature curve automatically updates every one hour, and the curve record can be stored for 60 days; Start from the latest curve saved time, if power is off and curve data collecting time is less than one hour, the data in this period will not be saved;...
  • Page 21: Parameter List And Breakdown Table

    4.OPERATION AND USE 4.3 Parameter list and breakdown table (1) Electronic control fault table Can be judged according to the remote controller failure code and troubleshooting Fault Protect/fault Reason Elimination methods display Standby Normal boot The temp. Sensor is broken Inlet Temp.
  • Page 22 4.OPERATION AND USE 1. Motor is in locked-rotor state 1.Change a new fan motor 2.The wire connection between 2.Check the wire connection and make sure Fan Motor2 Fault F032 DC-fan motor module and fan they are in good contact motor is in bad contact Communication Fault Speed control module and main E081...
  • Page 23: Interface Drawin

    4.OPERATION AND USE (2) Parameter list Meaning Remarks Default Adjustable Refrigeration target temperature set point 28℃ Adjustable Heating the target temperature set point 28℃ Automatic target temerature set point Adjustable 27℃ 4.4 Interface drawin (1) Wire control interface diagram and definition Sign Meaning 12V(power +)...
  • Page 24 4.OPERATION AND USE Main board of the input and output interface instructions below Meaning Number Sign OUT1 Compressor ( output 220-230VAC) OUT2 Water pump ( output 220-230VAC) OUT3 4-way valve ( output 220-230VAC) OUT4 High speed of fan ( output 220-230VAC) OUT5 Low speed of fan (output 220-230VAC)...
  • Page 25: Maintenance And Inspection

    5. MAINTENANCE AND INSPECTION Check the water supply device and the release often. You should avoid the condition of no water or air entering into system, as this will influence unit's performance and reliability. You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of clogged filter.
  • Page 26: Appendix

    6.APPENDIX 6.1 Caution & Warning 1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer.(for Europe market) 2. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 27: Cable Specification

    6.APPENDIX 6.2 Cable specification (1) Single phase unit Nameplate Creepage protector Signal line maximum Phase line Earth line current No more 2×1.5mm 1.5mm 30mA less than 0.1 sec than 10A 2×2.5mm 2.5mm 30mA less than 0.1 sec 10~16A 2×4mm 30mA less than 0.1 sec 16 ~25A 2×6mm 25 ~32A...
  • Page 28: Explosive View Of The Unit

    6.APPENDIX 6.3 Explosive view of the unit Model and code: OASIS Ci 10...
  • Page 29 6.APPENDIX Parts name Code pressure sensor 20000-360123 Needle 20000-140153 T-Pipe Needle 2000-1435 reducing straight-way 20000-140512 reducing straight-way 2002-1496 Filter pressure switch 20000-140058 pressure switch 2004-1444 check valve 2001-3605 4-way Valve and fittings Electronic Expansion Valve 20000-360157 electronic box 2001-1499 compressor 2004-1437 right panel flow switch...
  • Page 30 6.APPENDIX Model and code: OASIS Ci 13...
  • Page 31 6.APPENDIX Parts name Code pressure sensor 20000-360123 Needle 20000-140150 Needle Filter 20000-140512 pressure switch 2004-1444 pressure switch 20000-360157 4-way Valve and fittings Electronic Expansion Valve 2001-3605 electronic box 2004-1437 compressor 20000-140346 right panel flow switch 32009-220029 top cover 20000-110217 heat exchanger 32009-210399 Electrical Box Cover Supporting Plate...
  • Page 32 6.APPENDIX Model and code: OASIS Ci 17...
  • Page 33 6.APPENDIX Parts name Code pressure sensor 20000-360123 Needle 20000-140512 Needle T-Pipe 20000-140150 Colorful display 2000-1435 reducing straight-way 95005-310500 Chassis Filter 20000-140143 pressure switch 32018-210125 pressure switch 2004-1444 check valve 4-way Valve and fittings 20000-360157 Electronic Expansion Valve 2001-3605 electronic box 2001-1499 compressor right panel...
  • Page 34 6.APPENDIX Model and code: OASIS Ci 21 25 24...
  • Page 35 6.APPENDIX Parts name Code Front Plate 32019-210066 Colorful display 95005-310500 fan protection net Fan Guard 32018-210132 Fan Blade 32019-210065 back protection net 20000-270004 fan motor heat exchanger 32019-210068 Fan Motor Support 20000-330132 Supporting Plate 32019-120008 top cover Electrical Box Cover 32019-210063 Middle Plate 32019-210070...
  • Page 36 6.APPENDIX Model and code: OASIS Ci 25T 25 24...
  • Page 37 6.APPENDIX Code Part name Front late 32019-210066 Colorful display 95005-310500 an protection net Fan uard 32018-210132 Fan lade 32019-210065 ack protection net 20000-270004 an motor 32015-210028 eat exchanger otor upport 20000-330132 Supporting late 32015-120012 op cover Electrical ox over 32019-210063 Middle late 32019-210070 Electrical ox...
  • Page 38 Note:...
  • Page 40 Code:20170818-0002...

This manual is also suitable for:

Oasis ci 10Oasis ci 13Oasis ci 17Oasis ci 25t

Table of Contents