Oasis EH9h Installation Instructions Manual

Swimming pool heat pump unit
Hide thumbs Also See for EH9h:

Advertisement

Quick Links

All manuals and user guides at all-guides.com
SWIMMING POOL HEAT PUMP UNIT
Installation & Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for Oasis EH9h

  • Page 1 All manuals and user guides at all-guides.com SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual...
  • Page 2 All manuals and user guides at all-guides.com...
  • Page 3: Table Of Contents

    All manuals and user guides at all-guides.com CONTENTS 1. Preface 2. Specifications 2.1 Performance Data of Swimming Pool Heat Pump Unit 2.2 Dimensions for Swimming Pool Heat Pump Unit 3. Installation and Connection 3.1 Installation of System 3.2 Swimming Pool Heat Pumps Location 3.3 How Close to Your Pool? 3.4 Swimming Pool Heat Pumps Plumbing 3.5 Swimming Pool Heat Pumps Electrical Wiring...
  • Page 4: Preface

    All manuals and user guides at all-guides.com 1. PREFACE In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit.
  • Page 5: Specifications

    All manuals and user guides at all-guides.com 2.SPECIFICATION 2.1 Performance data of Swimming Pool Heat Pump Unit *** REFRIGERANT : R410A Unit Model EH9h EH9bp Oasis H13bp Heating Capacity 13.8 BTU/h 31400 31400 47000 Heating Power Input Running Current 10.4...
  • Page 6 All manuals and user guides at all-guides.com 2.SPECIFICATION *** REFRIGERANT : R410A Unit Model Oasis C21bp Oasis C25tbp Heating Capacity 21.0 BTU/h 88000 71715 Heating Power Input Running Current 17.5 Power Supply 380V/3N /50Hz 230V~/50Hz Compressor Quantity Compressor scroll Scroll...
  • Page 7: Dimensions For Swimming Pool Heat Pump Unit

    All manuals and user guides at all-guides.com 2.SPECIFICATION 2.2 The dimensions for Swimming Pool Heat Pump Unit Eh9h/9bp/Oasis H13bp/C13bp Water outlet Water inlet Oasis H17bp/C17bp/C21bp Water Outlet Water Inlet...
  • Page 8 All manuals and user guides at all-guides.com 2.SPECIFICATION Oasis C25sbp/C25tbp Water Outlet Water Inlet unit mm TYPE Oasis H17bp/C17bp/C21bp Eh9h/9bp/Oasis H13bp/C13bp Oasis C25sbp/C25tbp SIZE 1115 1002 1248...
  • Page 9: Installation And Connection

    All manuals and user guides at all-guides.com 3.INSTALLATION AND CONNECTION 3.1 Installation illustration Valve Chlorinator cell Water outlet Water supply Pool Water inlet Sand filter Water pump (or other type filter) Installation items: The factory only provides the main unit and the water unit; the other items in the illustration are necessary spare parts for the water system ,that provided by users or the installer.
  • Page 10: Swimming Pool Heat Pumps Location

    All manuals and user guides at all-guides.com 3.INSTALLATION AND CONNECTION 3.2 Swimming Pool Heat Pumps Location The unit will perform well in any outdoor location provided that the following three factors are presented: 1. Fresh Air - 2. Electricity - 3. Pool filter piping The unit may be installed virtually anywhere outdoors.
  • Page 11: Swimming Pool Heat Pumps Plumbing

    All manuals and user guides at all-guides.com 3.INSTALLATION AND CONNECTION 3.4 Swimming Pool Heat Pumps Plumbing The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special plumbing arrangements except bypass(please set the flow rate according to the nameplate).
  • Page 12: Swimming Pool Heat Pumps Electrical Wiring

    All manuals and user guides at all-guides.com 3.INSTALLATION AND CONNECTION 3.5 Swimming Pool Heat Pumps Electrical Wiring NOTE: Although the unit heat exchanger is electrically isolated from the rest of the unit, it simply prevents the flow of electricity to or from the pool water. Grounding the unit is still required to protect you against short circuits inside the unit.
  • Page 13: Usage And Operation

    All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 1.Function of controller Main display area TEMP MODE TEMP Aux. Display area 1 Button function NO Symbol Name Function Press this button can start up or shut down the unit, cancel the current operation or back to the upper On/off interface...
  • Page 14: Usage Of The Controller

    All manuals and user guides at all-guides.com 4. USAGE AND OPERATION Symbol Meaning Function Cooling It is showed when the unit in cooling mode. It is showed when the unit in heating mode and flashed Heating in defrosting. Automatic It is showed when the unit in automatic mode. It is showed when the unit in electric-heating mode.
  • Page 15 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 2.The controller usage Starting up and shutting down In the off interface, press" " for 0.5s can start up the unit, and aux. display-area shows water outlet temperature; In the running interface, press" "...
  • Page 16 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION Temperature setting In the main interface press and the current mode target-temperature flashes, then press to increase the temp.value, or press to decrease it. Press MODE can save setting parameter and back to the main interface Press can not save setting parameter but back to the main interface Attention If there is no operation for 5s system would remember parameter setting and...
  • Page 17 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION Hour minute Flashing TEMP TEMP Press MODE MODE TEMP TEMP Press Flashing Flashing Press TEMP TEMP MODE MODE TEMP TEMP Press to save hour Flashing Flashing value setting Press TEMP TEMP MODE...
  • Page 18 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 2.5 Timer setting In the main interface press hold on 2 seconds and "on" is flashing, at this time, you can set the timer on means the unit timer is on then press again and hold on 2 seconds and "off"...
  • Page 19 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION Flashing Flashing Flashing TEMP Press TEMP MODE MODE TEMP TEMP Press Flashing Flashing Flashing Flashing TEMP TEMP MODE MODE Press TEMP TEMP Press The timer on and off has been set Flashing Flashing TEMP TEMP...
  • Page 20 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 2.6 Cancel the timer setting Press for 2s and "ON" is flashing at this time, press to cancel the setting of timer on; It is the same way to cancel the setting of timer off . For example The timer on/off has been set "ON"...
  • Page 21 All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 2.4 Keyboard lock To avoid mis-operation, please lock the controller after parameter setting. At the main interface, press for 5 seconds, the keyboard will be locked. When the keyboard is locked, press for 5 seconds, the keyboard will be unlocked.
  • Page 22: Parameter Table

    All manuals and user guides at all-guides.com 4. USAGE AND OPERATION 3. Parameter table Default Remark Meaning Heating inlet target temp. Adjustable Cooling inlet target temp. Adjustable...
  • Page 23: Wiring Cliagram

    FM Fan motor FS Flow switch HP High pressure protection K1 Relay of compressor IT Inlet water temperature LP Low pressure protection Controller OT Outlet water temperature TC Transformer EH9h Soft start COMP RED BLU AI06 OUT3 OUT1 OUT2 AI05...
  • Page 24 FM Fan motor FS Flow switch KM1 Contacter of compressor HP High pressure protection IT Inlet water temperature LP Low pressure protection Controller OT Outlet water temperature TC Transformer Oasis H13bp Soft start COMP RED BLU AI06 OUT3 OUT1 OUT2...
  • Page 25 FS Flow switch HP High pressure protection IT Inlet water temperature KM1 Contacter of compressor Starting relay LP Low pressure protection OT Outlet water temperature SUT Suction temperature Controller Oasis H17bp COMP RED BLU AI06 OUT3 OUT1 OUT2 AI05 OUT4...
  • Page 26 HP High pressure protection IT Inlet water temperature KM1 Contacter of compressor Starting relay LP Low pressure protection OT Outlet water temperature SUT Suction temperature Controller 4 way valve Oasis C21bp COMP RED BLU AI06 OUT3 OUT1 OUT2 AI05 OUT4...
  • Page 27 HP High pressure protection AI01 IT Inlet water temperature KM1 Contactor of compressor KM2 Contactor of pump K4 Relay coil of fan LP Low pressure protection OT Outlet water temperature PM Phase monitor SUT Suctiontemperature Controller TC Transformer 4 way valve Oasis C25Tbp...
  • Page 28: Maintenance And Inspection

    All manuals and user guides at all-guides.com 5. MAINTENANCE AND INSPECTION 5.1 Maintenance Check the water supply device and the release often. You should avoid the condition of no water or air entering into system, as this will influence unit's performance and reliability. You should clear the pool/spa filter regularly to avoid damage to the unit as a result of the dirty of clogged filter.
  • Page 29: Trouble Shooting Guide

    All manuals and user guides at all-guides.com 5. MAINTENANCE AND INSPECTION 5.2 Trouble Shooting Guide Display Malfunction Canse Solution The water inlet temp. Sensor Check or change the water Water inlet temp. Sensor failure is open or short circuit inlet temp. Sensor Check or change the water The water outlet temp.
  • Page 30: Appendix

    All manuals and user guides at all-guides.com 6.APPENDIX 6.1 Connection of PCB illustration OUT1 OUT2 CN19 AI06 OUT3 AI05 OUT4 PC1001 PC1001 AI04 OUT5 AI03 AC-N AI02 AI01 CN16 Connections explanation Symbol Meaning Compressor of system1 220-230VAC OUT1 OUT2 Water pump 220-230VAC OUT3 4way valve 220-230VAC...
  • Page 31 All manuals and user guides at all-guides.com 6.APPENDIX Caution & Warning 1. The unit can only be repaired by qualified installer centre personnel or an authorised dealer. for Europe market 2. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 32 All manuals and user guides at all-guides.com 6.APPENDIX (2) Cable specification Single phase unit Nameplate Creepage protector Signal line maximum Phase line Earth line current No more than 13A 2 1.5mm 1.5mm 30mA less than 0.1 sec 30mA less than 0.1 sec 13~25A 2 4mm 2 6mm...
  • Page 33 All manuals and user guides at all-guides.com 6.APPENDIX 6.2 Explosive view of the unit MODEL Code Part name Note Code Part name Note Chassis 32012-210224 Top support plate 1 32012-210267 Front panel Water flow switch 32012-210266 20000-360005 LED water proof box 20000-220249 Handle 20000-220068...
  • Page 34 All manuals and user guides at all-guides.com 6.APPENDIX MODEL EH9bp Part name Note Code Part name Note Code Chassis 32012-210224 Top support plate 1 32012-210267 Front panel 20000-360005 Water flow switch 32012-210266 LED water proof box 20000-220249 Handle 20000-220068 Cm100 touch LCD 95005-310152 32012-210269 Right-side panel...
  • Page 35 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis 13bp Part name Code Note Code Part name Note Chassis 32012-210224 Top support plate 1 32012-210267 Front panel 20000-360005 Water flow switch 32012-210266 LED water proof box 20000-220249 Handle 20000-220068...
  • Page 36 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis C13bp Part name Code Note Code Part name Note Chassis 32012-210224 Top support plate 1 32012-210267 Front panel 20000-360005 Water flow switch 32012-210266 LED water proof box 20000-220249 Handle 20000-220068...
  • Page 37 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis H17bp 34 33 Code Part name Note Code Part name Note 20000-110208 ompressor 2000-3920 Three-seat connector 2000-2802 Pressure Gauge 2000-3933 Three-seat connector 3500-1401 Liquid-gas separator 20000-350004 Compressor capacitor 2004-1444 Filter...
  • Page 38 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis C17bp Code Part name Note Code Part name Note 20000-110208 ompressor 20000-220249 Junction box 2000-2802 Pressure Gauge 2000-3920 Three-seat connector 3500-1401 Liquid-gas separator 2000-3933 Three-seat connector Filter Compressor capacitor 2004-1444...
  • Page 39 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis C21bp Code Part name Note Code Part name Note 20000-110112 ompressor 20000-220249 Junction box 2000-2802 Pressure Gauge 2000-3920 Three-seat connector 3500-1401 Liquid-gas separator 2000-3933 Three-seat connector 2004-1444 Filter 20000-350004 Compressor capacitor...
  • Page 40 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis C25sbp Code Part name Note Code Part name Note 20000-110119 Compressor 2000-3619 Relay 32019-210045 Chassis 2000-3909 two-seat connector 2000-1440 Flash chamber 2000-3501 Fan capacitor 95005-310152 CM103 20000-370003 Transformer 20000-220188 Fan protection net...
  • Page 41 All manuals and user guides at all-guides.com 6.APPENDIX MODEL Oasis C25b p Code Part name Note Code Part name Note 20000-110140 Compressor 2000-3501 Fan capacitor 32019-210045 Chassis 20000-370003 Transformer 2000-1440 Flash chamber 20000-360023 3-phase AC R elay 95005-310152 CM103 2001-3602...
  • Page 42 All manuals and user guides at all-guides.com Note:...
  • Page 43 All manuals and user guides at all-guides.com...
  • Page 44 All manuals and user guides at all-guides.com Code 20140723-0002...

This manual is also suitable for:

Eh9bpH13bpC21bpC25tbpC25sbpC13bp ... Show all

Table of Contents