0 to 1000 ppm, alarm setting, pen type co meter

Advertisement

Quick Links

0 to 1000 PPM, alarm setting, pen type
CO METER
Model : PCO-350
OPERATION MANUAL
Your purchase of this
CO METER marks a step
forward for you into the
field
of
measurement. Although
this METER is a complex
and delicate instrument,
its durable structure will
allow many years of use
if
proper
t e c h n i q u e s
developed. Please read
t h e
f o l l o w i n g
instructions
and always keep this
manual
within
reach.
precision
operating
a r e
carefully
easy

Advertisement

Table of Contents
loading

Summary of Contents for Lutron Electronics PCO-350

  • Page 1 0 to 1000 PPM, alarm setting, pen type CO METER Model : PCO-350 Your purchase of this CO METER marks a step forward for you into the field precision measurement. Although this METER is a complex and delicate instrument, its durable structure will...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. FEATURES..............1 2. SPECIFICATIONS............1 2-1 General Specifications.......... 1 2-2 Electrical Specifications.........2 3. FRONT PANEL DESCRIPTION........3 3-1 CO Sensing Head..........3 3-2 Power Button............3 3-3 Hold Button............3 3-4 Alarm Button..........3-5 LCD Display............3 3-6 Battery Compartment/Cover......... 3 4.
  • Page 3: Features

    1. FEATURES * Two function : CO ( Carbon monoxide ), Temperature. * CO range : 0 to 1,000 PPM x 1 PPM. * Temperature. : 0 to 50 ℃ ℃ ℉ * CO measurement with fast response time. * High repeatability and high accuracy. * Pen type, easy to carryout and operation.
  • Page 4: Electrical Specifications

    Zero Build in zero button for offsetting the zero value Operating 0 to 50 ℃ Temperature Operating Less than 80% R.H. Humidity Power Supply DC 1.5 V battery ( UM4/AAA ) x 4 PCs. Power Current Approx. DC 4.0 mA Weight 194 g/ 0.43 LB.
  • Page 5: Front Panel Description

    3. FRONT PANEL DESCRIPTION Fig. 1 3-1 CO Sensing Head 3-2 Power Button 3-3 Hold Button 3-4 Alarm Button 3-5 LCD Display 3-6 Battery Compartment/Cover...
  • Page 6: Measuring Procedure

    4. MEASURING PROCEDURE 4-1 CO measurement 1)Power on the meter by pressing the " Power Button " ( 3-2, Fig. 1 ) once, * Press the " Power Button " once again will power off. 2)Locate the " CO sensing head " ( 3-1, Fig. 1 ) to the position that intend to make the measurement.
  • Page 7: Auto Power Off

    4-4 Auto power off In order to prolong the battery life, the instrument has "Auto Power Off " function. The meter will switch off automatically if no buttons are pressed for around 10 minutes. 4-5 Set the Temp. unit ( ) with default ℃...
  • Page 8: Battery Replacement

    5. BATTERY REPLACEMENT 1)Replace the batteries when the left corner of the LCD displays the low battery icon " ". 2)Prepare 4 fresh 1.5 V ( UM4, AAA ) batteries. 3)To change the batteries, open ( rotate clockwise direction ) the "...