Installation Of The Indoor Unit - Hisense KFR-3208GW Instruction & Installation Manual

Hisense owners manual room air conditioner kfr-3208gw
Table of Contents

Advertisement

Appendix: Installation

3. Installation of the indoor unit

Remove the wall plate
(1)Remove the fixing screws and keep them for future use (not used
during installation).
(2)Press the two triangular signs on the outer shell and remove the fixing
clip.
(3)Remove the wall plate.
Mount the wall plate
(1)Determine the correct position of the plate with a level (never use the
naked eyes!). The plate should be level.
(2)Fix the plate with §¶ 6mm expansion bolts for cement walls and with
wood screws for wood or plaster walls.
Caution: Adequate space should be reserved for the
installation of the indoor unit. To avoid running noise and
vibration, the wall plate should be fixed tightly on the wall.
Make the wall hole
Select the position of the hole according to the positions of the indoor and
outdoor units. The hole should be slightly lower than the wall plate.
The diameter of the hole is 65mm and the hole should be made with the
outside end a little lower.
The site should be cleaned after the hole is made.
Caution: Check carefully before the hole is drilled to make
sure that there is no cables or tubes in the area.
Connect the tubes of the indoor unit
A. Connect the electric wires
(1)Open the front panel and remove the cover of the electric box.
(2)Remove the wire clip in the electric box.
(3)Put in the wires from the back of the indoor unit and pull them out from the
front.
(4)Connect the wires firmly to the terminal panel.
(5)Fix the wires with the clip, replace the cover and close the front panel.
Caution: Make sure that the numbers of the terminals are the same
as those of the terminal panel.
B. Connect the tubes
(1)Do not let dust, dirt, air and water into the tubes during installation, so never
remove the tube plugs if installation is not due.
(2)Remove the nuts at the tube joints of the indoor unit, align the center of the
tube flare (apply anti-freezing oil on the cone head), tighten the cone-shaped
nuts with the hand first, then tighten up with a spanner.
Caution: Avoid leakage from loose connection or damage of
the flare from over-tightening.
Left tube
hole center
Set the outdoor unit
21
Wall plate
Fixing screw
Fixing clip
75
Indoor
Anti-freezing oil
is applied here
Connecting
tube
Set the indoor unit
Right tube
75
hole center
Outdoor
Flared
tube

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfr-3208ae

Table of Contents