Quick Start Guide
1.9
Flash source wiring
1.9.1
Install flash source wiring
To install the wiring:
Figure 1-6: Source with Cover Removed
A. Housing
B. Internal earth connection
C. Terminal board
D. Inlet conduit
E. Detector holding plate
F. Earth terminal
Procedure
1. Release the back screw bolt and open the source back cover.
2. Remove the protective plug mounted on the source conduit/cable
entry inlet; pull the wires through the source inlet.
3. Use a ¾-in.-14 national pipe thread (NPT) or M25 x 1.5 explosion-
proof conduit connection/cable gland to assemble the cable/
explosion-proof conduit to the detector.