General
Caution
The cartridge filter must never be removed
during vacuuming.
When the dirt water reaches the highest
permissible level in the container, the
suction power is interrupted.
After having completed the wet vacuum
operation clean the cartridge filter, the
mechanical overflow safeguard and the
container and let dry.
If you change immediately from wet to
dry vacuuming, then replace the wet
cartridge filter with a dry one.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.
Operation
Turning on the Appliance
 Plug in the main plug.
 Turn on the appliance.
Turn off the appliance.
 Turn off the appliance.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside.
Storing the Appliance
 Wind the suction hose and the mains ca-
ble and hang it over the pushing handle.
 Place the appliance in a dry room and
secure it from unauthorized use.
14
Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
 Remove the suction pipe with the floor
nozzle from the holder. Hold the appli-
ance by the handle and at the suction pipe
to transport it, not by the push handle.
 Pull the device behind you at the carry-
ing handle for transporting it over longer
distances
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Maintenance and care
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Change cartridge filter
 Release and remove the suction head.
 Unscrew the star screw, pull out the car-
tridge filter and replace with a new one.
 Tighten the star screw.
 Insert and lock the suction head.
Cleaning the mechanical overflow
 Release and remove the suction head.
 Unscrew the star scew and pull out the
cartridge filter.
 Clean the mechanical overflow safe-
guard
 Replace the cartridge filters.
 Tighten the star screw.
 Insert and lock the suction head.
– 3