LCD DISPLAY
DIAGNOSIS
Hazard Indicator Error
Running Lights Error
Speed Limit Warning
Low Battery
Idle Mode
Attendant Control Error
Battery Charging or Drive
Inhibit - Joystick Powered
On
Battery Charging or Drive
Inhibit - Joystick Powered
Off
System Lock Mode. The
NE+ controller is locked
out.
Drive Inhibit.
SOLUTION
Press hazard key. See Section 2. Contact
Quantum Technical Service for further trou-
bleshooting.
Press light key. See Section 2. Contact
Quantum Technical Service for further trou-
bleshooting.
Return seat to normal or upright position.
See Section 2. Contact Quantum Technical
Service for further troubleshooting.
Recharge batteries.
Cycle power. If it continues, contact Tech
Service. See Section 2. Contact Quantum
Technical Service for further troubleshoot-
ing.
Check Attendant Control connections and
wiring. See Section 2. Contact Quantum
Technical Service for further troubleshoot-
ing.
Unplug charger when charging is complete.
Check connections. See Section 2.
Unplug charger when charging is complete.
Check connections. See Section 2.
The NE+ controller is locked out and must
be unlocked. See Section 2.
Check power module connections. See Sec-
tion 2.