Table 22 — 50RHR,RVR Coaxial
Water Pressure Drop
UNIT
GPM
30 F
50RHR,RVR
0.8
006*
1.1
1.5
1.1
009
1.7
2.2
1.5
012
2.3
3.0
1.8
015
2.6
3.5
2.3
019
3.4
4.5
3.0
024
4.5
6.0
3.8
030
5.5
7.5
4.5
036
6.8
9.0
5.3
042
7.9
10.5
6.0
048
9.0
12.0
7.5
060
11.3
15.0
*Size 006 available in 50RHR unit only.
Table 23 — 50RHS,RVS,RDS Coaxial
Water Pressure Drop
UNIT
GPM
50RHS,RVS,RDS
1.8
015
2.8
3.8
2.2
018
3.5
4.5
3.0
024
4.5
6.0
3.7
030
5.5
7.5
4.5
036
7.0
9.0
5.2
042
8.0
10.5
6.0
048
9.0
12.0
7.5
060
11.3
15.0
9.0
070
13.5
18.0
WATER TEMPERATURE (F)
50 F
70 F
90 F
Pressure Drop (psi)
0.8
0.8
0.7
0.7
1.2
1.1
1.0
1.0
2.0
1.9
1.8
1.7
1.2
1.1
1.0
0.9
1.7
1.6
1.5
1.4
3.5
3.2
3.0
2.8
2.8
2.6
2.4
2.3
6.0
5.6
5.2
4.9
9.6
9.0
8.3
7.9
2.5
2.3
2.1
2.0
4.8
4.5
4.1
3.9
8.1
7.6
7.0
6.6
1.9
1.7
1.6
1.5
3.4
3.1
2.9
2.7
6.6
6.2
5.7
5.4
2.0
1.9
1.7
1.6
4.2
3.9
3.6
3.4
7.0
6.5
6.0
5.7
1.4
1.3
1.2
1.2
2.4
2.3
2.1
2.0
3.9
3.7
3.4
3.2
1.1
1.1
1.0
0.9
2.1
2.0
1.9
1.8
3.5
3.3
3.0
2.9
1.4
1.3
1.2
1.2
2.9
2.7
2.5
2.3
4.6
4.2
3.9
3.7
2.1
1.9
1.8
1.7
3.9
3.7
3.4
3.2
6.4
5.9
5.5
5.2
2.9
2.7
2.5
2.4
5.7
5.3
4.9
4.7
9.4
8.7
8.1
7.7
WATER TEMPERATURE (F)
30 F
50 F
70 F
90 F
Pressure Drop (psi)
0.6
0.5
0.5
1.0
0.9
0.8
1.5
1.4
1.3
0.7
0.7
0.6
1.3
1.2
1.1
1.8
1.8
1.6
0.6
0.6
0.5
1.1
1.1
1.0
1.8
1.7
1.5
0.8
0.8
0.7
1.6
1.4
1.3
2.6
2.4
2.2
1.3
1.2
1.1
2.1
1.9
1.8
3.9
3.7
3.4
1.6
1.5
1.4
3.2
3.0
2.8
5.1
4.7
4.4
2.1
1.9
1.8
3.9
3.7
3.4
6.4
5.9
5.5
1.1
1.0
1.0
2.2
2.1
1.9
3.6
3.4
3.1
1.5
1.4
1.3
3.0
2.8
2.6
5.0
4.7
4.3
Table 24 — 50RHC,RVC Coaxial
UNIT
50RHC,RVC
006*
009
012
018
024
030
036
041†
042
048
060
0.5
*Size 006 available in 50RHC unit only.
0.8
1.2
†Size 041 available in 50RVC unit only.
0.6
1.1
Antifreeze —
1.5
drop below 40 F or where piping will be routed through areas
0.5
subject to freezing, antifreeze is needed.
0.9
1.5
Alcohols and glycols are commonly used as antifreeze
0.7
agents. Freeze protection should be maintained to 15 F below
1.3
2.1
the lowest expected entering loop temperature. For example, if
1.1
the lowest expected entering loop temperature is 30 F, the leav-
1.7
ing loop temperature would be 22 to 25 F. Therefore, the freeze
3.2
protection should be at 15 F (30 F – 15 F = 15 F).
1.3
2.6
4.1
IMPORTANT: All alcohols should be pre-mixed and
1.7
pumped from a reservoir outside of the building or
3.2
5.2
introduced under water level to prevent fuming.
0.9
1.8
3.0
Calculate the total volume of fluid in the piping system. See
1.2
Table 25. Use the percentage by volume in Table 26 to deter-
2.5
4.1
mine the amount of antifreeze to use. Antifreeze concentration
should be checked from a well mixed sample using a hydrome-
ter to measure specific gravity.
FREEZE PROTECTION SELECTION — The 30 F FP1
factory setting (water) should be used to avoid freeze damage
to the unit.
Once antifreeze is selected, the JW3 jumper (FP1) should
be clipped on the control to select the low temperature (anti-
freeze 13 F) set point to avoid nuisance faults.
35
Water Pressure Drop
WATER TEMPERATURE (F)
GPM
60 F
70 F
Pressure Drop (psi)
0.9
0.7
0.7
1.1
1.2
1.2
1.7
1.9
1.9
2.0
2.9
2.8
1.1
2.4
2.3
1.7
3.1
3.0
2.3
4.0
3.9
3.0
5.4
5.3
1.5
2.3
2.2
2.3
4.4
4.3
3.0
6.4
6.2
4.0
13.3
12.9
2.3
2.0
2.0
3.5
3.1
3.0
4.5
4.2
4.1
6.0
5.9
5.7
3.0
2.0
1.9
4.5
3.9
3.7
6.0
6.4
6.2
8.0
10.6
10.3
3.8
1.5
1.5
5.5
2.7
2.6
7.5
4.3
4.2
10.0
6.9
6.7
4.5
1.7
1.7
6.8
3.2
3.1
9.0
5.0
4.9
12.0
8.2
7.9
5.3
0.9
0.9
7.9
2.2
2.1
10.5
4.0
3.9
13.0
6.2
6.0
5.3
1.0
1.0
8.0
2.6
2.6
11.0
5.3
5.1
14.0
8.7
8.5
6.0
1.2
1.2
9.0
2.9
2.8
12.0
5.3
5.1
16.0
9.5
9.2
7.5
4.4
4.2
11.3
7.6
7.3
15.0
11.4
11.1
20.0
17.6
17.1
In areas where entering loop temperatures
80 F
90 F
0.7
0.6
1.2
1.1
1.8
1.8
2.7
2.6
2.3
2.2
2.9
2.8
3.8
3.7
5.1
4.9
2.1
2.1
4.2
4.0
6.0
5.8
12.6
12.2
1.9
1.8
2.9
2.8
3.9
3.8
5.6
5.4
1.8
1.8
3.6
3.5
6.0
5.8
10.0
9.7
1.4
1.4
2.5
2.4
4.1
3.9
6.5
6.3
1.6
1.6
3.0
2.9
4.8
4.6
7.7
7.5
0.9
0.9
2.1
2.0
3.8
3.6
5.8
5.7
1.0
0.9
2.5
2.4
4.9
4.8
8.2
8.0
1.2
1.1
2.7
2.6
4.9
4.8
8.9
8.6
4.1
4.0
7.1
6.9
10.8
10.4
16.6
16.1

Hide quick links:

Advertisement

Table of Contents
loading