Carrier AQUAZONE 50RHC Installation And Service Instructions Manual page 11

Water source heat pump units
Hide thumbs Also See for AQUAZONE 50RHC:
Table of Contents

Advertisement

OVERALL CABINET
50RVR
UNITS
A
B
Width
Depth
in.
22.4
21.6
009-012
cm
56.8
54.9
in.
22.4
21.6
015-024
cm
56.8
54.9
in.
22.4
25.6
030
cm
56.8
65.1
in.
22.4
25.6
036
cm
56.8
65.1
in.
22.4
25.6
042-048
cm
56.8
65.1
in.
25.4
30.6
060
cm
64.5
77.8
NOTES:
1. Condensate is
3
/
-in. FPT and is switchable from side to front.
4
2. Vertical unit shipped with filter bracket only extending from unit 2.5 inches. This bracket should be removed when connecting return duct.
3. Discharge flange field installed.
4. Right and left orientation is determined by looking at water connection side.
RIGHT RETURN
M
L
N
Air Coil Side
R Configuration - Top View-Right Return
P
R
Q
C
ASP
Front
R Configuration - Right Return Right View
- Air Coil Opening
AIRFLOW CONFIGURATION
Code
Return
L
Left
R
Right
WATER CONNECTIONS
1
2
3
Loop
Water
F
FPT
C
D
E
Cond-
(in.)
Height
In
Out
ensate
22.6
2.6
5.4
7.8
1
/
2
57.4
6.6
13.7
19.8
34.6
2.4
4.8
8.5
3
/
87.9
6.1
12.2
21.6
4
40.6
2.4
5.4
9.7
3
/
4
103.1
6.1
13.7
24.6
40.6
2.4
5.4
9.7
3
/
4
103.1
6.1
13.7
24.6
48.6
2.4
5.4
9.7
1
123.4
6.1
13.7
24.6
50.6
2.4
5.4
10.7
1
128.5
6.1
13.7
27.2
ASP — Alternate Service Panel
BSP — Blower Service Panel
CAP — Control Access Panel
CSP — Compressor Service Panel
LEFT RETURN
K
K
Air Coil Side
L Configuration - Top View-Left Return
O
O
R
Air Coil
Q
C
Back
Back
L Configuration - Left Return Left View
- Air Coil Opening
Discharge
Top
Top
Fig. 6 — 50RVR Dimensional Data
ELECTRICAL KNOCKOUTS (in.)
G
H
I
1
1
3
/
conduit
/
conduit
/
conduit
2
2
4
Power
Therm
Ext Pump
Supply
3.5
5.5
8.2
10.6
8.9
14.0
20.8
26.9
3.5
7.5
10.2
8.9
19.1
25.9
18.3
5.7
9.7
12.2
14.5
24.6
31.0
18.3
5.7
9.7
12.2
14.5
24.6
31.0
18.3
5.7
9.7
12.2
14.5
24.6
31.0
18.3
8.1
11.7
14.2
20.6
29.7
36.1
15.7
LEGEND
Standard Filter Bracket
Air Coil
B
M
L
A
J
P
Air Coil
Power Supply
3/4" HV Knockout
Power for
Condensate Pump
1/2
Knockout
"
Low Voltage
CSP
1/2" LV Knockout
Front
11
DISCHARGE CONNECTION
RETURN CONNECTION
Duct Flange Installed (±0.10 in.)
Using Air Coil Opening
L
M
J
K
Supply
Supply
N
O
Height
Depth
6.8
5.8
8.0
6.0 2.2
17.3
14.7
20.3
15.2 5.6
7.2
3.8
14.0
14.0
4.3 2.2
9.7
35.6
35.6
10.9 5.6
7.2
5.8
14.0
14.0
4.3 2.2
14.7
35.6
35.6
10.9 5.6
7.2
5.8
14.0
14.0
4.3 2.2
14.7
35.6
35.6
10.9 5.6
7.2
5.8
14.0
14.0
4.3 2.2
14.7
35.6
35.6
10.9 5.6
6.2
6.3
18.0
18.0
5.1 2.2
16.0
45.7
45.7
13.0 5.6
Field Installed
Water Connection
Discharge Flange
(Shipped loose in
Access Panels
blower section)
BSP
CSP
CAP
Front
3' Service
Isometric
Access
View
CAP
3
I
H
2
CSP
G
1
Front View
a50-8159
P
Q
Return
Return
R
Depth
Height
17.1
9.3
1.0
43.4
23.6
2.5
17.1
15.3
1.0
43.4
38.9
2.5
21.1
19.2
1.0
53.6
48.8
2.5
21.1
19.2
1.0
53.6
48.8
2.5
21.1
27.2
1.0
53.6
69.1
2.5
26.1
27.2
1.0
66.3
69.1
2.5
ASP
3' Service
Access
Left Return
ASP
(right
Opposite)
Water
Connections
1.000
Condensate
3/4
"
FPT
F
E
D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents