TRANSPORT, LIFTING AND HANDLING OF THE UNITS
D A N G E R
Start-up and Operation:
Maintenance:
Maximum Allowable Pressure and High Pressure Cut-out Value:
Refrigerant
R410A
N O T E
Location of high pressure switch
High pressure switch
Accumulator
5 TRANSPORT, LIFTING AND HANDLING OF THE UNITS
5.1 TRANSPORT OF OUTDOOR UNIT
Corrugated paper
frame
Do not remove
corrugated paper
frame and plastic
bands
When using a crane, hang the unit according to the description
of the label attached to the outdoor unit.
The unit shall not be handled by one person. Do not use the PP
band to move the unit although the unit is packed by PP band.
Additionally, do not touch the heat exchanger with bare hands.
7
PMML0479 rev.2 - 02/2018
Maximun Allowable Pressure (MPa)
4.15
Compressor
Apply rope on the cloths
or corrugated papers
more than 15 mm in
thickness.
Wooden base
D A N G E R
High Pressure Switch Cut-out Value (MPa)
N O T E
Structure of High Pressure switch
Contact point
Connected to the electrical switch
follow the instructions below in order to prevent the unit
deformation.
Do not step or put any material on the product. It may cause
injury.
Apply two sling belts onto the outdoor unit, when lifting it with
a crane.
To protect the unit, do not remove any packing.
Do not stack or put any material on the product.
Apply wire ropes on both sides of the unit as shown in the
C A U T I O N
4.00 ~ 4.10
Pressure detected